Precision of the virtual occlusal record

dc.contributor.authorBotsford, Keyan P.
dc.contributor.authorFrazier, Michael C.
dc.contributor.authorGhoneima, Ahmed A.M.
dc.contributor.authorUtreja, Achint
dc.contributor.authorBhamidipalli, Surya S.
dc.contributor.authorStewart, Kelton T.
dc.contributor.departmentOrthodontics and Oral Facial Genetics, School of Dentistryen_US
dc.date.accessioned2022-10-12T11:38:07Z
dc.date.available2022-10-12T11:38:07Z
dc.date.issued2019-09
dc.description.abstractObjectives: To evaluate the precision of the virtual occlusal record using the Carestream CS3600 Intraoral Scanner (Carestream Dental, Atlanta, Ga). Materials and methods: A total of 20 participants were recruited for this prospective study using preestablished inclusion/exclusion criteria. A complete intraoral scan and two bite registrations were obtained. The participants were instructed to bite with normal pressure when bite registrations were acquired. Contact locations, size (circumference), and intensity were identified on the maxillary first molars and canines. Agreement between contact size and intensity was assessed with intraclass correlation coefficients. Kappa statistics evaluated agreement in contact locations. Statistical significance was set at P < .05. Results: All participant data were included for statistical analysis. Between the two bite registrations, nonstatistically significant differences were observed in the proportion of locations with contacts (P = .7681). A nonstatistically significant difference (-0.25 mm, P = .8416) in mean contact circumference size was observed. A statistically significant difference in mean contact intensity was observed (P = .0448). When evaluating agreement between the bite registrations, a weak correlation for size (intraclass correlation coefficient = 0.35) and intensity (intraclass correlation coefficient = 0.32) was observed as well as a moderate agreement for contact location (κ coefficient = 0.67). Conclusions: The findings suggest that the Carestream intraoral scanner software possesses adequate precision when acquiring the location and size of the contacts in bite registrations. The scanner failed to demonstrate adequate precision when acquiring contact intensities in bite registrations. Additional research is warranted to further investigate the precision of virtual occlusal records with currently available software systems.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationBotsford KP, Frazier MC, Ghoneima AAM, Utreja A, Bhamidipalli SS, Stewart KT. Precision of the virtual occlusal record. Angle Orthod. 2019;89(5):751-757. doi:10.2319/092018-684.1en_US
dc.identifier.urihttps://hdl.handle.net/1805/30329
dc.language.isoen_USen_US
dc.publisherAllen Pressen_US
dc.relation.isversionof10.2319/092018-684.1en_US
dc.relation.journalThe Angle Orthodontisten_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectBite registrationen_US
dc.subjectIntraoral scanneren_US
dc.subjectPrecisionen_US
dc.subjectVirtual occlusal recorden_US
dc.titlePrecision of the virtual occlusal recorden_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
i0003-3219-89-5-751.pdf
Size:
262.2 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: