Precision of the virtual occlusal record

Date
2019-09
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Allen Press
Abstract

Objectives: To evaluate the precision of the virtual occlusal record using the Carestream CS3600 Intraoral Scanner (Carestream Dental, Atlanta, Ga).

Materials and methods: A total of 20 participants were recruited for this prospective study using preestablished inclusion/exclusion criteria. A complete intraoral scan and two bite registrations were obtained. The participants were instructed to bite with normal pressure when bite registrations were acquired. Contact locations, size (circumference), and intensity were identified on the maxillary first molars and canines. Agreement between contact size and intensity was assessed with intraclass correlation coefficients. Kappa statistics evaluated agreement in contact locations. Statistical significance was set at P < .05.

Results: All participant data were included for statistical analysis. Between the two bite registrations, nonstatistically significant differences were observed in the proportion of locations with contacts (P = .7681). A nonstatistically significant difference (-0.25 mm, P = .8416) in mean contact circumference size was observed. A statistically significant difference in mean contact intensity was observed (P = .0448). When evaluating agreement between the bite registrations, a weak correlation for size (intraclass correlation coefficient = 0.35) and intensity (intraclass correlation coefficient = 0.32) was observed as well as a moderate agreement for contact location (κ coefficient = 0.67).

Conclusions: The findings suggest that the Carestream intraoral scanner software possesses adequate precision when acquiring the location and size of the contacts in bite registrations. The scanner failed to demonstrate adequate precision when acquiring contact intensities in bite registrations. Additional research is warranted to further investigate the precision of virtual occlusal records with currently available software systems.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Botsford KP, Frazier MC, Ghoneima AAM, Utreja A, Bhamidipalli SS, Stewart KT. Precision of the virtual occlusal record. Angle Orthod. 2019;89(5):751-757. doi:10.2319/092018-684.1
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
The Angle Orthodontist
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}