Serial high sensitivity cardiac troponin T measurement in acute heart failure: insights from the RELAX-AHF study

dc.contributor.authorFelker, G. Michael
dc.contributor.authorMentz, Robert J.
dc.contributor.authorTeerlink, John R.
dc.contributor.authorVoors, Adriaan A.
dc.contributor.authorPang, Peter S.
dc.contributor.authorPonikowski, Piotr
dc.contributor.authorGreenberg, Barry H.
dc.contributor.authorFilippatos, Gerasimos
dc.contributor.authorDavison, Beth A.
dc.contributor.authorCotter, Gad
dc.contributor.authorPrescott, Margaret F.
dc.contributor.authorHua, Tsushung A.
dc.contributor.authorLopez-Pintado, Sara
dc.contributor.authorSeverin, Thomas
dc.contributor.authorMetra, Marco
dc.contributor.departmentDepartment of Emergency Medicine, IU School of Medicineen_US
dc.date.accessioned2016-04-22T15:47:36Z
dc.date.available2016-04-22T15:47:36Z
dc.date.issued2015-12
dc.description.abstractAims Troponin elevation is common in acute heart failure (AHF) and may be useful for prognostication; however, available data are mixed and many previous studies used older, less sensitive assays. We examined the association between serial measurements of high-sensitivity cardiac troponin T (hs-cTnT) and outcomes in RELAX-AHF. Methods and results Hs-cTnT was measured at baseline and days 2, 5, and 14. We assessed the relationship between baseline, peak and peak change hs-cTnT with dyspnoea relief by visual analogue scale, cardiovascular death, or HF/renal hospitalization to 60 days and cardiovascular mortality to 180 days. Models were adjusted for clinical variables and treatment assignment. Whether baseline troponin status affected the treatment effect of serelaxin was assessed using interactions terms. In 1074 patients, the median baseline troponin was 0.033 µg/L, and 90% of patients were above the 99th upper reference limit (URL). Patients with hs-cTnT >median were more likely to be men with ischaemic heart disease, worse renal function, and higher N-terminal pro-brain natriuretic peptide. Higher baseline or peak hs-cTnT and greater peak change were associated with worse outcomes independent of adjustment for covariates, but relationships were generally strongest for 180-day cardiovascular mortality (hazard ratio per doubling of baseline hs-cTnT = 1.36, 95% confidence interval 1.15–1.60). Troponin was most strongly associated with death from heart failure or from other cardiovascular causes. The treatment effect of serelaxin did not differ by baseline troponin levels. Conclusion Hs-cTnT was elevated above the 99% URL in the majority of AHF patients. Baseline, peak, and peak change hs-cTnT were associated with worse outcomes, with the strongest relationship with 180-day cardiovascular mortality.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationFelker, G. M., Mentz, R. J., Teerlink, J. R., Voors, A. A., Pang, P. S., Ponikowski, P., … Metra, M. (2015). Serial high sensitivity cardiac troponin T measurement in acute heart failure: insights from the RELAX-AHF study. European Journal of Heart Failure, 17(12), 1262–1270. http://doi.org/10.1002/ejhf.341en_US
dc.identifier.urihttps://hdl.handle.net/1805/9383
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1002/ejhf.341en_US
dc.relation.journalEuropean Journal of Heart Failureen_US
dc.sourceAuthoren_US
dc.subjecthigh-sensitivity cardiac troponin Ten_US
dc.subjectacute heart failureen_US
dc.titleSerial high sensitivity cardiac troponin T measurement in acute heart failure: insights from the RELAX-AHF studyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Felker_2015_serial.pdf
Size:
395.56 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: