In vitro Detection of Occlusal Caries on Permanent Teeth by a Visual, Light-Induced Fluorescence and Photothermal Radiometry and Modulated Luminescence Methods

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2015-10
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Karger
Abstract

Background: The paradigm shift towards the nonsurgical management of dental caries relies on the early detection of the disease. Detection of caries at an early stage is of unequivocal importance for early preventive intervention. Objective: The aim of this in vitro study is to evaluate the performance of a visual examination using the International Caries Detection and Assessment System (ICDAS) criteria, two quantitative light-induced fluorescence (QLF) systems - Inspektor™ Pro and QLF-D Biluminator™ 2 (Inspektor Research Systems B.V., Amsterdam, The Netherlands) - and a photothermal radiometry and modulated luminescence, The Canary System® (Quantum Dental Technologies, Toronto, Ont., Canada) on the detection of primary occlusal caries on permanent teeth. Methods: A total of 60 teeth with occlusal surface sites ranging from sound to noncavitated lesions (ICDAS 0-4) were assessed with each detection method twice in a random order. Histological validation was used to compare methods for sensitivity, specificity, percent correct, and the area under the receiver operating characteristic curve (AUC), at standard and optimum sound thresholds. Interexaminer agreement and intraexaminer repeatability were measured using intraclass correlation coefficients. Results: Interexaminer agreement ranged between 0.48 (The Canary System®) and 0.96 (QLF-D Biluminator™ 2). Intraexaminer repeatability ranges were 0.33-0.63 (The Canary System®) and 0.96-0.99 (QLF-D Biluminator™ 2). The sensitivity range was 0.75-0.96 while that of specificity was 0.43-0.89. The AUC were 0.79 (The Canary System®), 0.87 (ICDAS), 0.90 (Inspektor™ Pro), and 0.94 (QLF-D Biluminator™ 2). Conclusion: ICDAS had the best combination of sensitivity and specificity followed by QLF-D Biluminator™ 2 at optimum threshold.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Jallad, M., Zero, D., Eckert, G., & Ferreira Zandona, A. (2015). In vitro Detection of Occlusal Caries on Permanent Teeth by a Visual, Light-Induced Fluorescence and Photothermal Radiometry and Modulated Luminescence Methods. Caries Research, 49(5), 523–530. http://doi.org/10.1159/000437214
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Caries Research
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}