Evaluation of electromechanical impedance based structural health monitoring for detection of loosening in total knee arthroplasty

dc.contributor.authorPonder, Robert I.
dc.contributor.authorMeneghini, R. Michael
dc.contributor.authorAnton, Steven R.
dc.contributor.departmentOrthopaedic Surgery, School of Medicineen_US
dc.date.accessioned2020-07-02T19:38:53Z
dc.date.available2020-07-02T19:38:53Z
dc.date.issued2019
dc.description.abstractTotal Knee Arthroplasty (TKA) continues to be a common and important orthopedic procedure for many in the United States. Despite recent medical advancements and increasing knowledge in the orthopedic community, it has been determined that 20% of TKA patients are still dissatisfied with their knee replacements. Causes of this failure include septic loosening and wear on the bearing component of the implant. Another cause of failure that has received specific attention from the mechanical community is aseptic loosening, which has been attributed to unbalanced ligaments or misalignment of the implant components. Previous efforts have been made to detect loosening by using passive force sensors such as piezoelectric transducers or strain gauges to detect misalignment. An alternative to this is to perform active sensing or structural health monitoring to evaluate possible loosening before it becomes a critical concern to the patient. One method of structural health monitoring, called the electromechanical impedance (EMI) method, is particularly attractive as it can use a single, compact piezoelectric transducer to determine the state of the host structure. This work is intended to evaluate the ability of the EMI method in sensing loosening between the cement and bone of a TKA tibial tray. This work will utilize real tibial trays implanted into synthetic bone (Sawbone) to evaluate the feasibility of detecting loosening using the EMI method. The intention of this work is to serve as a foundation for further in-vivo and intraoperative studies.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationPonder, R. I., Meneghini, R. M., & Anton, S. R. (2019). Evaluation of electromechanical impedance based structural health monitoring for detection of loosening in total knee arthroplasty. Health Monitoring of Structural and Biological Systems XIII, 10972, 1097226. https://doi.org/10.1117/12.2514053en_US
dc.identifier.urihttps://hdl.handle.net/1805/23173
dc.language.isoenen_US
dc.publisherSPIEen_US
dc.relation.isversionof10.1117/12.2514053en_US
dc.relation.journalHealth Monitoring of Structural and Biological Systems XIIIen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectstructural health monitoringen_US
dc.subjectpiezoelectricen_US
dc.subjectimpedanceen_US
dc.subjecttotal knee replacementen_US
dc.titleEvaluation of electromechanical impedance based structural health monitoring for detection of loosening in total knee arthroplastyen_US
dc.typeConference proceedingsen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ponder2019Evaluation.pdf
Size:
662.67 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: