Evaluation of electromechanical impedance based structural health monitoring for detection of loosening in total knee arthroplasty

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2019
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
SPIE
Abstract

Total Knee Arthroplasty (TKA) continues to be a common and important orthopedic procedure for many in the United States. Despite recent medical advancements and increasing knowledge in the orthopedic community, it has been determined that 20% of TKA patients are still dissatisfied with their knee replacements. Causes of this failure include septic loosening and wear on the bearing component of the implant. Another cause of failure that has received specific attention from the mechanical community is aseptic loosening, which has been attributed to unbalanced ligaments or misalignment of the implant components. Previous efforts have been made to detect loosening by using passive force sensors such as piezoelectric transducers or strain gauges to detect misalignment. An alternative to this is to perform active sensing or structural health monitoring to evaluate possible loosening before it becomes a critical concern to the patient. One method of structural health monitoring, called the electromechanical impedance (EMI) method, is particularly attractive as it can use a single, compact piezoelectric transducer to determine the state of the host structure. This work is intended to evaluate the ability of the EMI method in sensing loosening between the cement and bone of a TKA tibial tray. This work will utilize real tibial trays implanted into synthetic bone (Sawbone) to evaluate the feasibility of detecting loosening using the EMI method. The intention of this work is to serve as a foundation for further in-vivo and intraoperative studies.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Ponder, R. I., Meneghini, R. M., & Anton, S. R. (2019). Evaluation of electromechanical impedance based structural health monitoring for detection of loosening in total knee arthroplasty. Health Monitoring of Structural and Biological Systems XIII, 10972, 1097226. https://doi.org/10.1117/12.2514053
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Health Monitoring of Structural and Biological Systems XIII
Source
Author
Alternative Title
Type
Conference proceedings
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}