Abstract

OBJECTIVE. The purpose of this study is to compare conventional duplex ultrasound and contrast-enhanced ultrasound (CEUS) for identifying vascular abnormalities in pancreas allografts in the immediate posttransplant setting. Identification of pancreas allografts at risk of failure may impact patient care because early intervention for vascular insufficiency can lead to graft salvage. MATERIALS AND METHODS. Two radiologists who were blinded to patient outcomes performed a retrospective analysis of the postoperative Doppler ultrasound and CEUS images of 34 pancreas grafts from transplants performed between 2017 and 2019. A total of 28 patients who did not require surgical reexploration were considered the control group. Six patients had surgically proven arterial or venous abnormalities on surgical reexploration. Each radiologist scored grafts as having normal or abnormal vascularity on the basis of image sets obtained using Doppler ultrasound only and CEUS only. Comparisons of both the diagnostic performance of each modality and interobserver agreement were performed. RESULTS. Both readers showed that CEUS had increased sensitivity for detecting vascular abnormalities (83.3% for both readers) compared with Doppler ultrasound (66.7% and 50.0%). For both readers, the specificity of CEUS was similar to that of Doppler imaging (81.6% and 78.9% for reader 1 and reader 2 versus 76.3% and 84.2% for reader 1 and reader 2). For both readers, the negative predictive value of CEUS was higher than that of Doppler ultrasound (96.9% and 96.8% for reader 1 and reader 2 versus 93.5% and 91.4% for reader 1 and reader 2). Interobserver agreement was higher for CEUS than for Doppler ultrasound (κ = 0.54 vs κ = 0.28). CONCLUSION. CEUS may provide radiologists and surgeons with a means of timely and effective evaluation of pancreas graft perfusion after surgery, and it may help identify grafts that could benefit from surgical salvage.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Swensson J, Hill D, Tirkes T, Fridell J, Patel A. Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts. AJR Am J Roentgenol. 2020;215(5):1093-1097. doi:10.2214/AJR.20.22858
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
American Journal of Roentgenology
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}