High-sensitivity intravascular photoacoustic imaging of lipid-laden plaque with a collinear catheter design

dc.contributor.authorCao, Yingchun
dc.contributor.authorHui, Jie
dc.contributor.authorKole, Ayeeshik
dc.contributor.authorWang, Pu
dc.contributor.authorYu, Qianhuan
dc.contributor.authorChen, Weibiao
dc.contributor.authorSturek, Michael
dc.contributor.authorCheng, Ji-Xin
dc.contributor.departmentDepartment of Cellular & Integrative Physiology, IU School of Medicineen_US
dc.date.accessioned2017-07-12T19:11:03Z
dc.date.available2017-07-12T19:11:03Z
dc.date.issued2016-04-28
dc.description.abstractA highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter housing for the first time. Such collinear catheter design with an outer diameter of 1.6 mm provided highly efficient overlap between optical and acoustic waves over an imaging depth of >6 mm in D2O medium. Intravascular photoacoustic imaging of lipid-laden atherosclerotic plaque and perivascular fat was demonstrated, where a lab-built 500 Hz optical parametric oscillator outputting nanosecond optical pulses at a wavelength of 1.7 μm was used for overtone excitation of C-H bonds. In addition to intravascular imaging, the presented catheter design will benefit other photoacoustic applications such as needle-based intramuscular imaging.en_US
dc.identifier.citationCao, Y., Hui, J., Kole, A., Wang, P., Yu, Q., Chen, W., … Cheng, J.-X. (2016). High-sensitivity intravascular photoacoustic imaging of lipid–laden plaque with a collinear catheter design. Scientific Reports, 6, 25236. http://doi.org/10.1038/srep25236en_US
dc.identifier.urihttps://hdl.handle.net/1805/13412
dc.language.isoen_USen_US
dc.publisherSpringerNatureen_US
dc.relation.isversionof10.1038/srep25236en_US
dc.relation.journalScientific Reportsen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/
dc.sourcePMCen_US
dc.subjectCatheter-based intravascular photoacoustic imagingen_US
dc.subjectCatheter probesen_US
dc.subjectCollinear catheter designen_US
dc.subjectPhotoacousticsen_US
dc.titleHigh-sensitivity intravascular photoacoustic imaging of lipid-laden plaque with a collinear catheter designen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
srep25236.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format
Description:
Main Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: