Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function

dc.contributor.authorPowell, C.R.
dc.contributor.departmentUrology, School of Medicineen_US
dc.date.accessioned2019-05-06T20:13:27Z
dc.date.available2019-05-06T20:13:27Z
dc.date.issued2018-08-20
dc.description.abstractPURPOSE OF REVIEW: Sacral neuromodulation (SNM) is being used to treat lower urinary tract symptoms (LUTS) with growing popularity among clinicians in multiple specialties. As this therapy becomes more common in the USA and Europe, urologists will encounter more patients implanted with SNM generators. RECENT FINDINGS: Over time, it has recently been understood that up to 53% will develop pain at the implant site as reported by Groen et al. (J Urol 186:954, 2011) and 3-38% will lose effective stimulation as reported by Al-zahrani et al. (J Urol 185:981, 2011) and White et al. (Urology 73:731, 2009). There is a paucity of troubleshooting methodology in the literature, apart from revision surgery, to salvage the SNM generator. In fact, it has been suggested that one contemporary series' failure rate is lower than some historic series because of the ability to reprogram devices as reported by Siegel et al. (J Urol 199:229, 2018). Standard algorithms for such reprogramming efforts are lacking in the literature and may salvage some patients otherwise destined for surgical revision or addition of multimodal therapy to achieve acceptable symptom control. It is possible to troubleshoot and thereby salvage many SNM generators, saving patients from surgical revision in many cases and increasing the number of patients with persistent benefit from SNM. The algorithms presented in this manuscript represent a systematic strategy for reprogramming and troubleshooting SNM generators.en_US
dc.identifier.citationPowell C. R. (2018). Troubleshooting Interstim Sacral Neuromodulation Generators to Recover Function. Current urology reports, 19(10), 86. doi:10.1007/s11934-018-0837-5en_US
dc.identifier.urihttps://hdl.handle.net/1805/19145
dc.language.isoen_USen_US
dc.publisherSpringer Natureen_US
dc.relation.isversionof10.1007/s11934-018-0837-5en_US
dc.relation.journalCurrent Urology reportsen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourcePMCen_US
dc.subjectNeuromodulationen_US
dc.subjectUrinary incontinenceen_US
dc.subjectUrinary urgencyen_US
dc.subjectUrinary frequencyen_US
dc.subjectBladderen_US
dc.subjectProsthesis and implantsen_US
dc.subjectElectric stimulationen_US
dc.subjectEquipment safetyen_US
dc.titleTroubleshooting Interstim Sacral Neuromodulation Generators to Recover Functionen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
11934_2018_Article_837.pdf
Size:
1.31 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: