Development of a Generic Physiologically-Based Pharmacokinetic Model for Lactation and Prediction of Maternal and Infant Exposure to Ondansetron via Breast Milk

dc.contributor.authorJob, Kathleen M.
dc.contributor.authorDallmann, André
dc.contributor.authorParry, Samuel
dc.contributor.authorSaade, George
dc.contributor.authorHaas, David M.
dc.contributor.authorHughes, Brenna
dc.contributor.authorBerens, Pamela
dc.contributor.authorChen, Jia-Yu
dc.contributor.authorFu, Christina
dc.contributor.authorHumphrey, Kelsey
dc.contributor.authorHornik, Christoph
dc.contributor.authorBalevic, Stephen
dc.contributor.authorZimmerman, Kanecia
dc.contributor.authorWatt, Kevin
dc.contributor.departmentObstetrics and Gynecology, School of Medicine
dc.date.accessioned2024-01-24T11:41:32Z
dc.date.available2024-01-24T11:41:32Z
dc.date.issued2022
dc.description.abstractOndansetron is commonly used in breastfeeding mothers to treat nausea and vomiting. There is limited information in humans regarding safety of ondansetron exposure to nursing infants and no adequate study looking at ondansetron pharmacokinetics during lactation. We developed a generic physiologically based pharmacokinetic lactation model for small molecule drugs and applied this model to predict ondansetron transfer into breast milk and characterize infant exposure. Drug-specific model inputs were parameterized using data from the literature. Population-specific inputs were derived from a previously conducted systematic literature review of anatomic and physiologic changes in postpartum women. Model predictions were evaluated using ondansetron plasma and breast milk concentration data collected prospectively from 78 women in the Commonly Used Drugs During Lactation and infant Exposure (CUDDLE) study. The final model predicted breast milk and plasma exposures following a single 4 mg dose of intravenous ondansetron in 1000 simulated women who were two days postpartum. Model predictions showed good agreement with observed data. Breast milk median prediction error (MPE) was 18.4% and median absolute prediction error (MAPE) was 53.0%. Plasma MPE was 32.5% and MAPE was 43.2%. The model-predicted daily and relative infant doses were 0.005 mg/kg/day and 3.0%, respectively. This model adequately predicted ondansetron passage into breast milk. The calculated low relative infant dose indicates that mothers receiving ondansetron can safely breastfeed. The model building blocks and population database are open-source and can be adapted to other drugs.
dc.eprint.versionAuthor's manuscript
dc.identifier.citationJob KM, Dallmann A, Parry S, et al. Development of a Generic Physiologically-Based Pharmacokinetic Model for Lactation and Prediction of Maternal and Infant Exposure to Ondansetron via Breast Milk. Clin Pharmacol Ther. 2022;111(5):1111-1120. doi:10.1002/cpt.2530
dc.identifier.urihttps://hdl.handle.net/1805/38149
dc.language.isoen_US
dc.publisherWiley
dc.relation.isversionof10.1002/cpt.2530
dc.relation.journalClinical Pharmacology & Therapeutics
dc.rightsPublisher Policy
dc.sourcePMC
dc.subjectOndansetron
dc.subjectPhysiological based pharmacokinetic model
dc.subjectLactation
dc.subjectPostpartum
dc.titleDevelopment of a Generic Physiologically-Based Pharmacokinetic Model for Lactation and Prediction of Maternal and Infant Exposure to Ondansetron via Breast Milk
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1857478.pdf
Size:
1.28 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: