Development of a Generic Physiologically-Based Pharmacokinetic Model for Lactation and Prediction of Maternal and Infant Exposure to Ondansetron via Breast Milk

Abstract

Ondansetron is commonly used in breastfeeding mothers to treat nausea and vomiting. There is limited information in humans regarding safety of ondansetron exposure to nursing infants and no adequate study looking at ondansetron pharmacokinetics during lactation. We developed a generic physiologically based pharmacokinetic lactation model for small molecule drugs and applied this model to predict ondansetron transfer into breast milk and characterize infant exposure. Drug-specific model inputs were parameterized using data from the literature. Population-specific inputs were derived from a previously conducted systematic literature review of anatomic and physiologic changes in postpartum women. Model predictions were evaluated using ondansetron plasma and breast milk concentration data collected prospectively from 78 women in the Commonly Used Drugs During Lactation and infant Exposure (CUDDLE) study. The final model predicted breast milk and plasma exposures following a single 4 mg dose of intravenous ondansetron in 1000 simulated women who were two days postpartum. Model predictions showed good agreement with observed data. Breast milk median prediction error (MPE) was 18.4% and median absolute prediction error (MAPE) was 53.0%. Plasma MPE was 32.5% and MAPE was 43.2%. The model-predicted daily and relative infant doses were 0.005 mg/kg/day and 3.0%, respectively. This model adequately predicted ondansetron passage into breast milk. The calculated low relative infant dose indicates that mothers receiving ondansetron can safely breastfeed. The model building blocks and population database are open-source and can be adapted to other drugs.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Job KM, Dallmann A, Parry S, et al. Development of a Generic Physiologically-Based Pharmacokinetic Model for Lactation and Prediction of Maternal and Infant Exposure to Ondansetron via Breast Milk. Clin Pharmacol Ther. 2022;111(5):1111-1120. doi:10.1002/cpt.2530
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Clinical Pharmacology & Therapeutics
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}