Simulation of blood flow past a distal arteriovenous-graft anastomosis at low Reynolds numbers

dc.contributor.authorBai, Zengding
dc.contributor.authorZhu, Luoding
dc.contributor.departmentMathematical Sciences, School of Scienceen_US
dc.date.accessioned2020-11-06T18:11:54Z
dc.date.available2020-11-06T18:11:54Z
dc.date.issued2019-09
dc.description.abstractPatients with end-stage renal disease are usually treated by hemodialysis while waiting for a kidney transplant. A common device for vascular access is an arteriovenous graft (AVG). However, AVG failure induced by thrombosis has been plaguing dialysis practice for decades. Current studies indicate that the thrombosis is caused by intimal hyperplasia, which is triggered by the abnormal flows and forces [e.g., wall shear stress (WSS)] in the vein after AVG implant. Due to the high level of complexity, in almost all of the existing works of modeling and simulation of the blood-flow vessel-AVG system, the graft and blood vessel are assumed to be rigid and immobile. Very recently, we have found that the compliance of graft and vein can reduce flow disturbances and lower WSS [Z. Bai and L. Zhu, “Three-dimensional simulation of a viscous flow past a compliant model of arteriovenous-graft anastomosis,” Comput. Fluids 181, 403–415 (2019)]. In this paper, we apply the compliant model to investigate possible effects of several dimensionless parameters (AVG graft-vein diameter ratio Rgv, AVG attaching angle θ, flow Reynolds numbers Re, and native vein speed Vv) on the flow and force fields near the distal AVG anastomosis at low Reynolds numbers (up to several hundreds). Our computational results indicate that the influences of the parameters Rgv, θ, and Re lie largely on the graft and the influence of Vv lies largely on the vein. In any case, the WSS, wall shear stress gradient, and wall normal stress gradient and their averaged values on the graft are significantly greater than those on the vein. ACKNOWLEDGMENTSen_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationBai, Z., & Zhu, L. (2019). Simulation of blood flow past a distal arteriovenous-graft anastomosis at low Reynolds numbers. Physics of Fluids, 31(9), 091902. https://doi.org/10.1063/1.5099635en_US
dc.identifier.urihttps://hdl.handle.net/1805/24292
dc.language.isoenen_US
dc.publisherAIPen_US
dc.relation.isversionof10.1063/1.5099635en_US
dc.relation.journalPhysics of Fluidsen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectend-stage renal diseaseen_US
dc.subjectdialysisen_US
dc.subjectarteriovenous graften_US
dc.titleSimulation of blood flow past a distal arteriovenous-graft anastomosis at low Reynolds numbersen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bai_2019_simulation.pdf
Size:
40.82 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: