Simulation of blood flow past a distal arteriovenous-graft anastomosis at low Reynolds numbers

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2019-09
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
AIP
Abstract

Patients with end-stage renal disease are usually treated by hemodialysis while waiting for a kidney transplant. A common device for vascular access is an arteriovenous graft (AVG). However, AVG failure induced by thrombosis has been plaguing dialysis practice for decades. Current studies indicate that the thrombosis is caused by intimal hyperplasia, which is triggered by the abnormal flows and forces [e.g., wall shear stress (WSS)] in the vein after AVG implant. Due to the high level of complexity, in almost all of the existing works of modeling and simulation of the blood-flow vessel-AVG system, the graft and blood vessel are assumed to be rigid and immobile. Very recently, we have found that the compliance of graft and vein can reduce flow disturbances and lower WSS [Z. Bai and L. Zhu, “Three-dimensional simulation of a viscous flow past a compliant model of arteriovenous-graft anastomosis,” Comput. Fluids 181, 403–415 (2019)]. In this paper, we apply the compliant model to investigate possible effects of several dimensionless parameters (AVG graft-vein diameter ratio Rgv, AVG attaching angle θ, flow Reynolds numbers Re, and native vein speed Vv) on the flow and force fields near the distal AVG anastomosis at low Reynolds numbers (up to several hundreds). Our computational results indicate that the influences of the parameters Rgv, θ, and Re lie largely on the graft and the influence of Vv lies largely on the vein. In any case, the WSS, wall shear stress gradient, and wall normal stress gradient and their averaged values on the graft are significantly greater than those on the vein. ACKNOWLEDGMENTS

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Bai, Z., & Zhu, L. (2019). Simulation of blood flow past a distal arteriovenous-graft anastomosis at low Reynolds numbers. Physics of Fluids, 31(9), 091902. https://doi.org/10.1063/1.5099635
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Physics of Fluids
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}