Reuse of Personal Protective Equipment: Results of a Human Factors Study Using Fluorescence to Identify Self‐Contamination During Donning and Doffing

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2022-03
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background At least 115,000 health and care workers (HCWs) are estimated to have lost their lives to COVID-19, according to the the chief of the World Health Organization (WHO). Personal protective equipment (PPE) is the first line of defense for HCWs against infectious diseases. At the height of the pandemic, PPE supplies became scarce, necessitating reuse, which increased the occupational COVID-19 risks to HCWs. Currently, there are few robust studies addressing PPE reuse and practice variability, leaving HCWs vulnerable to accidental contamination and harm.

Objective The objective of this study was to assess potential HCW contamination during PPE donning, doffing, and reuse.

Methods The study included 28 active acute care physicians, nurses, and nurse practitioners that evaluated 5 simulated patients with COVID-like symptoms while donning and doffing PPE between each patient encounter. An N95 mask was contaminated with a transparent fluorescent gel applied to the outside of the N95 mask to simulate contamination that might occur during reuse. Participants were evaluated after PPE doffing for each encounter using a black light to assess for face and body contamination.

Results All participants had multiple sites of contamination, predominantly on their head and neck. None of the participants were able to don and doff PPE without contaminating themselves during five consecutive simulation cycles.

Conclusions The current Centers for Disease Control and Prevention PPE guidelines for donning and doffing fall short in protecting HCWs. They do not adequately protect HCWs from contamination. There is an urgent need for PPE and workflow redesign.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Doos, D., Barach, P., Sarmiento, E., & Ahmed, R. (2022). Reuse of Personal Protective Equipment: Results of a Human Factors Study Using Fluorescence to Identify Self‐Contamination During Donning and Doffing. The Journal of Emergency Medicine, 62(3), 337–341. https://doi.org/10.1016/j.jemermed.2021.12.010
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Emergency Medicine
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
This item is under embargo {{howLong}}