Mapping explosive residues on galvanized pipe bomb fragments using total vaporization solid phase microextraction (TV-SPME)

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2015-12
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Royal Society of Chemistry
Abstract

Solid phase microextraction (SPME) is a popular sampling technique whereby analytes are sorbed to a coated fiber and subsequently desorbed into an analytical instrument. In headspace SPME, analytes partition between the sample, the headspace above the sample, and the SPME fiber coating. In total vaporization SPME (TV-SPME), sample extracts are heated until both the solvent and analytes completely vaporize, whereupon the analytes partition between the vapor phase and the SPME fiber. In this study, TV-SPME using a polyethylene glycol fiber was coupled with fast gas chromatography/mass spectrometry to identify components of double-base smokeless powder (DBSP). Nitroglycerin (NG), diphenylamine (DPA) and ethyl centralite (EC) were separated in under 5 min. For NG, the optimal sample volume (70 μL), extraction temperature (60 °C) and extraction time (20 min) resulted in a method that was over twelve fold more sensitive than traditional liquid injection and with a detection limit below 1 ppb. This method was then used to quantify DBSP residue on post-blast debris from five galvanized steel pipe bombs. The mean concentration of NG on the fragments was 0.25 ppm (w/w). An average of 1.01 mg of NG was recovered from the devices. Finally, the distribution of NG could be “mapped” by tracking the original locations of each fragment within the device. These maps showed that the distribution of NG was far from uniform. In fact, the concentration of the NG on fragments originating from the end caps was several fold higher than in other locations. This finding can help guide the selection of bomb fragments for chemical analyses in real-world scenarios.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Bors, D., & Goodpaster, J. (2015). Mapping explosive residues on galvanized pipe bomb fragments using total vaporization solid phase microextraction (TV-SPME). Analytical Methods, 7(23), 9756–9762. http://doi.org/10.1039/C5AY02358K
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Analytical Methods
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}