ScholarWorksIndianapolis
  • Communities & Collections
  • Browse ScholarWorks
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Connors, Bret A."

Now showing 1 - 10 of 15
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Comparison of Tissue Injury from Focused Ultrasonic Propulsion of Kidney Stones Versus Extracorporeal Shock Wave Lithotripsy
    (Elsevier, 2014-01) Connors, Bret A.; Evan, Andrew P.; Blomgren, Philip M.; Hsi, Ryan S.; Harper, Jonathan D.; Sorensen, Mathew D.; Wang, Yak-Nam; Simon, Julianna C.; Paun, Marla; Starr, Frank; Cunitz, Bryan W.; Bailey, Michael R.; Lingeman, James E.; Department of Anatomy & Cell Biology, IU School of Medicine
    Purpose Focused ultrasonic propulsion is a new non-invasive technique designed to move kidney stones and stone fragments out of the urinary collecting system. However, the extent of tissue injury associated with this technique is not known. As such, we quantitated the amount of tissue injury produced by focused ultrasonic propulsion under simulated clinical treatment conditions, and under conditions of higher power or continuous duty cycles, and compared those results to SWL injury. Materials and Methods A human calcium oxalate monohydrate stone and/or nickel beads were implanted (with ureteroscopy) into 3 kidneys of live pigs (45–55 kg) and repositioned using focused ultrasonic propulsion. Additional pig kidneys were exposed to SWL level pulse intensities or continuous ultrasound exposure of 10 minutes duration (ultrasound probe either transcutaneous or on the kidney). These kidneys were compared to 6 kidneys treated with an unmodified Dornier HM3 Lithotripter (2400 shocks, 120 SWs/min and 24 kV). Histological analysis was performed to assess the volume of hemorrhagic tissue injury created by each technique (% functional renal volume, FRV). Results SWL produced a lesion of 1.56±0.45% FRV. Ultrasonic propulsion produced no detectable lesion with the simulated clinical treatment. A lesion of 0.46±0.37% FRV or 1.15±0.49% FRV could be produced if excessive treatment parameters were used while the ultrasound probe was placed on the kidney. Conclusions Focused ultrasonic propulsion produced no detectable morphological injury to the renal parenchyma when using clinical treatment parameters and produced injury comparable in size to SWL when using excessive treatment parameters.
  • Loading...
    Thumbnail Image
    Item
    Development of a Novel Magnetic Resonance Imaging Acquisition and Analysis Workflow for the Quantification of Shock Wave Lithotripsy-Induced Renal Hemorrhagic Injury
    (Springer, 2017-10) Handa, Rajash K.; Territo, Paul R.; Blomgren, Philip M.; Persohn, Scott A.; Lin, Chen; Johnson, Cynthia D.; Jiang, Lei; Connors, Bret A.; Hutchins, Gary D.; Anatomy and Cell Biology, School of Medicine
    Introduction The current accepted standard for quantifying shock wave lithotripsy (SWL)-induced tissue damage is based on morphometric detection of renal hemorrhage in serial tissue sections from fixed kidneys. This methodology is time and labor intensive and is tissue destructive. We have developed a non-destructive magnetic resonance imaging (MRI) method that permits rapid assessment of SWL-induced hemorrhagic lesion volumes in post-mortem kidneys using native tissue contrast to reduce cycle time. Methods Kidneys of anesthetized pigs were targeted with shock waves using the Dornier Compact S lithotripter. Harvested kidneys were then prepared for tissue injury quantification. T1 weighted (T1W) and T2 weighted (T2W) images were acquired on a Siemens 3T Tim Trio MRI scanner. Images were co-registered, normalized, difference (T1W–T2W) images generated, and volumes classified and segmented using a Multi-Spectral Neural Network (MSNN) classifier. Kidneys were then subjected to standard morphometric analysis for measurement of lesion volumes. Results Classifications of T1W, T2W and difference image volumes were correlated with morphometric measurements of whole kidney and parenchymal lesion volumes. From these relationships, a mathematical model was developed that allowed predictions of the morphological parenchymal lesion volume from MRI whole kidney lesion volumes. Predictions and morphology were highly correlated (R=0.9691, n=20) and described by the relationship y=0.84x+0.09, and highly accurate with a sum of squares difference error of 0.79%. Conclusions MRI and the MSNN classifier provide a semi-automated segmentation approach, which provide a rapid and reliable means to quantify renal injury lesion volumes due to SWL.
  • Loading...
    Thumbnail Image
    Item
    Effect of renal shock wave lithotripsy on the development of metabolic syndrome in a juvenile swine model: a pilot study
    (Elsevier, 2015-04) Handa, Rajash K.; Liu, Ziyue; Connors, Bret A.; Alloosh, Mouhamad; Basile, David P.; Tune, Johnathan D.; Sturek, Michael; Evan, Andrew P.; Lingeman, James E.; Department of Anatomy & Cell Biology, IU School of Medicine
    PURPOSE: We performed a pilot study to assess whether renal shock wave lithotripsy influences metabolic syndrome onset and severity. MATERIALS AND METHODS: Three-month-old juvenile female Ossabaw miniature pigs were treated with shock wave lithotripsy (2,000 shock waves at 24 kV with 120 shock waves per minute in 2) or sham shock wave lithotripsy (no shock waves in 2). Shock waves were targeted to the upper pole of the left kidney to model treatment that would also expose the pancreatic tail to shock waves. Pigs were then instrumented to directly measure arterial blood pressure via an implanted radiotelemetry device. They later received a hypercaloric atherogenic diet for about 7 months. Metabolic syndrome development was assessed by the intravenous glucose tolerance test. RESULTS: Metabolic syndrome progression and severity were similar in the sham treated and lithotripsy groups. The only exception arterial blood pressure, which remained relatively constant in sham treated pigs but began to increase at about 2 months towards hypertensive levels in lithotripsy treated pigs. Metabolic data on the 2 groups were pooled to provide a more complete assessment of metabolic syndrome development and progression in this juvenile pig model. The intravenous glucose tolerance test revealed substantial insulin resistance with impaired glucose tolerance within 2 months on the hypercaloric atherogenic diet with signs of further metabolic impairment at 7 months. CONCLUSIONS: These preliminary results suggest that renal shock wave lithotripsy is not a risk factor for worsening glucose tolerance or diabetes mellitus onset. However, it appears to be a risk factor for early onset hypertension in metabolic syndrome.
  • Loading...
    Thumbnail Image
    Item
    Evaluation of an experimental electrohydraulic discharge device for extracorporeal shock wave lithotripsy: Pressure field of sparker array
    (Acoustical Society of America, 2017-11) Li, Guangyan; Connors, Bret A.; Schaefer, Ray B.; Gallagher, John J.; Evan, Andrew P.; Anatomy and Cell Biology, School of Medicine
    In this paper, an extracorporeal shock wave source composed of small ellipsoidal sparker units is described. The sparker units were arranged in an array designed to produce a coherent shock wave of sufficient strength to fracture kidney stones. The objective of this paper was to measure the acoustical output of this array of 18 individual sparker units and compare this array to commercial lithotripters. Representative waveforms acquired with a fiber-optic probe hydrophone at the geometric focus of the sparker array indicated that the sparker array produces a shock wave (P+ ∼40-47 MPa, P- ∼2.5-5.0 MPa) similar to shock waves produced by a Dornier HM-3 or Dornier Compact S. The sparker array's pressure field map also appeared similar to the measurements from a HM-3 and Compact S. Compared to the HM-3, the electrohydraulic technology of the sparker array produced a more consistent SW pulse (shot-to-shot positive pressure value standard deviation of ±4.7 MPa vs ±3.3 MPa).
  • Loading...
    Thumbnail Image
    Item
    Evaluation of shock wave lithotripsy injury in the pig using a narrow focal zone lithotriptor
    (Wiley, 2012) Connors, Bret A.; McAteer, James A.; Evan, Andrew P.; Blomgren, Philip M.; Handa, Rajash K.; Johnson, Cynthia D.; Gao, Sujuan; Pishchalnikov, Yuri A.; Lingeman, James E.; Anatomy, Cell Biology and Physiology, School of Medicine
    What's known on the subject? and What does the study add? Of all the SW lithotriptors manufactured to date, more research studies have been conducted on and more is known about the injury (both description of injury and how to manipulate injury size) produced by the Dornier HM-3 than any other machine. From this information have come suggestions for treatment protocols to reduce shock wave (SW)-induced injury for use in stone clinics. By contrast, much less is known about the injury produced by narrow-focus and high-pressure lithotriptors like the Storz Modulith SLX. In fact, a careful study looking at the morphology of the injury produced by the SLX itself is lacking, as is any study exploring ways to reduce renal injury by manipulating SW delivery variables of this lithotriptor. The present study quantitates the lesion size and describes the morphology of the injury produced by the SLX. In addition, we report that reducing the SW delivery rate, a manoeuvre known to lower injury in the HM-3, does not reduce lesion size in the SLX. Objective: • To assess renal injury in a pig model after treatment with a clinical dose of shock waves using a narrow focal zone (≈3 mm) lithotriptor (Modulith SLX, Karl Storz Lithotripsy). Materials and methods: • The left kidney of anaesthetized female pigs were treated with 2000 or 4000 shock waves (SWs) at 120 SWs/min, or 2000 SWs at 60 SWs/min using the Storz SLX. • Measures of renal function (glomerular filtration rate and renal plasma flow) were collected before and 1 h after shock wave lithotripsy (SWL) and the kidneys were harvested for histological analysis and morphometric quantitation of haemorrhage in the renal parenchyma with lesion size expressed as a percentage of functional renal volume (FRV). • A fibre-optic probe hydrophone was used to determine acoustic output and map the focal width of the lithotriptor. • Data for the SLX were compared with data from a previously published study in which pigs of the same age (7-8 weeks) were treated (2000 SWs at 120 or 60 SWs/min) using an unmodified Dornier HM3 lithotriptor. Results: • Treatment with the SLX produced a highly focused lesion running from cortex to medulla and often spanning the full thickness of the kidney. Unlike the diffuse interstitial haemorrhage observed with the HM3, the SLX lesion bore a blood-filled core of near-complete tissue disruption devoid of histologically recognizable kidney structure. • Despite the intensity of tissue destruction at the core of the lesion, measures of lesion size based on macroscopic determination of haemorrhage in the parenchyma were not significantly different from kidneys treated using the HM3 (2000 SWs, 120 SWs/min: SLX, 1.86 ± 0.52% FRV; HM3, 3.93 ± 1.29% FRV). • Doubling the SW dose of the SLX from 2000 to 4000 SWs did not significantly increase lesion size. In addition, slowing the firing rate of the SLX to 60 SWs/min did not reduce the size of the lesion (2.16 ± 0.96% FRV) compared with treatment at 120 SWs/min, as was the case with the HM3 (0.42 ± 0.23% FRV vs 3.93 ± 1.29% FRV). • Renal function fell significantly below baseline in all treated groups but was similar for both lithotriptors. • Focal width of the SLX (≈2.6 mm) was about one-third that of the HM3 (≈8 mm) while peak pressures were higher (SLX at power level 9: P+≈90 MPa, P-≈-12 MPa; HM3 at 24 kV: P+≈46 MPa, P-≈-8 MPa). Conclusions: • The lesion produced by the SLX (narrow focal width, high acoustic pressure) was a more focused, more intense form of tissue damage than occurs with the HM3. • Slowing the SW rate to 60 SWs/min, a strategy shown to be effective in reducing injury with the HM3, was not protective with the SLX. • These findings suggest that the focal width and acoustic output of a lithotriptor affect the renal response to SWL.
  • Loading...
    Thumbnail Image
    Item
    Functional and Morphological Changes Associated with Burst Wave Lithotripsy-Treated Pig Kidneys
    (Mary Ann Liebert Inc., 2022-11-28) Connors, Bret A.; Gardner, Tony; Liu, Ziyue; Lingeman, James E.; Kreider, Wayne; Williams , James C.; Biostatistics and Health Data Science, Richard M. Fairbanks School of Public Health
    Purpose: Burst wave lithotripsy (BWL) is a new technique for comminution of urinary stones. This technology is noninvasive, has a low positive pressure magnitude, and is thought to produce minor amounts of renal injury. However, little is known about the functional changes related to BWL treatment. In this study, we sought to determine if clinical BWL exposure produces a functional or morphological change in the kidney. Materials and Methods: Twelve female pigs were prepared for renal clearance assessment and served as either sham time controls (6) or were treated with BWL (6). In the treated group, 1 kidney in each pig was exposed to 18,000 pulses at 10 pulses/s with 20 cycles/pulse. Pressure levels related to each pulse were 12 and −7 MPa. Inulin (glomerular filtration rate, GFR) and para-aminohippuric acid (effective renal plasma flow, eRPF) clearance was measured before and 1 hour after treatment. Lesion size analysis was performed to assess the volume of hemorrhagic tissue injury created by each treatment (% FRV). Results: No visible gross hematuria was observed in any of the collected urine samples of the treated kidneys. BWL exposure also did not lead to a change in GFR or eRPF after treatment, nor did it cause a measurable amount of hemorrhage in the tissue. Conclusion: Using the clinical treatment parameters employed in this study, BWL did not cause an acute change in renal function or a hemorrhagic lesion.
  • Loading...
    Thumbnail Image
    Item
    Intraluminal measurement of papillary duct urine pH, in vivo: a pilot study in the swine kidney
    (Springer, 2016-06) Handa, Rajash K.; Lingeman, James E.; Bledsoe, Sharon B.; Evan, Andrew P.; Connors, Bret A.; Johnson, Cynthia D.; Department of Anatomy and Cell Biology, School of Medicine
    We describe the in vivo use of an optic-chemo microsensor to measure intraluminal papillary duct urine pH in a large mammal. Fiber-optic pH microsensors have a tip diameter of 140-µm that allows insertion into papillary Bellini ducts to measure tubule urine proton concentration. Anesthetized adult pigs underwent percutaneous nephrolithotomy to access the lower pole of the urinary collecting system. A flexible nephroscope was advanced towards an upper pole papilla with the fiber-optic microsensor contained within the working channel. The microsensor was then carefully inserted into Bellini ducts to measure tubule urine pH in real time. We successfully recorded tubule urine pH values in five papillary ducts from three pigs (1 farm pig and 2 metabolic syndrome Ossabaw pigs). Our results demonstrate that optical microsensor technology can be used to measure intraluminal urine pH in real time in a living large mammal. This opens the possibility for application of this optical pH sensing technology in nephrolithiasis.
  • Loading...
    Thumbnail Image
    Item
    Mechanism by which shock wave lithotripsy can promote formation of human calcium phosphate stones
    (American Physiological Society, 2015-04-15) Evan, Andrew P.; Coe, Fredric L.; Connors, Bret A.; Handa, Rajash K.; Lingeman, James E.; Worcester, Elaine M.; Department of Anatomy & Cell Biology, IU School of Medicine
    Human stone calcium phosphate (CaP) content correlates with higher urine CaP supersaturation (SS) and urine pH as well as with the number of shock wave lithotripsy (SWL) treatments. SWL does damage medullary collecting ducts and vasa recta, sites for urine pH regulation. We tested the hypothesis that SWL raises urine pH and therefore Cap SS, resulting in CaP nucleation and tubular plugging. The left kidney (T) of nine farm pigs was treated with SWL, and metabolic studies were performed using bilateral ureteral catheters for up to 70 days post-SWL. Some animals were given an NH4Cl load to sort out effects on urine pH of CD injury vs. increased HCO3 (-) delivery. Histopathological studies were performed at the end of the functional studies. The mean pH of the T kidneys exceeded that of the control (C) kidneys by 0.18 units in 14 experiments on 9 pigs. Increased HCO3 (-) delivery to CD is at least partly responsible for the pH difference because NH4Cl acidosis abolished it. The T kidneys excreted more Na, K, HCO3 (-), water, Ca, Mg, and Cl than C kidneys. A single nephron site that could produce losses of all of these is the thick ascending limb. Extensive injury was noted in medullary thick ascending limbs and collecting ducts. Linear bands showing nephron loss and fibrosis were found in the cortex and extended into the medulla. Thus SWL produces tubule cell injury easily observed histopathologically that leads to functional disturbances across a wide range of electrolyte metabolism including higher than control urine pH.
  • Loading...
    Thumbnail Image
    Item
    Optimising an escalating shockwave amplitude treatment strategy to protect the kidney from injury during shockwave lithotripsy
    (Wiley, 2012) Handa, Rajash K.; McAteer, James A.; Connors, Bret A.; Liu, Ziyue; Lingeman, James E.; Evan, Andrew P.; Anatomy, Cell Biology and Physiology, School of Medicine
    Study Type--Therapy (case series) Level of Evidence 4. What's known on the subject? and What does the study add? Animal studies have shown that one approach to reduce SWL-induced renal injury is to pause treatment for 3-4 min early in the SWL-treatment protocol. However, there is typically no pause in treatment during clinical lithotripsy. We show in a porcine model that a pause in SWL treatment is unnecessary to achieve a reduction in renal injury if treatment is begun at a low power setting that generates low-amplitude SWs, and given continuously for ≈ 4 min before applying higher-amplitude SWs. Objective: • To test the idea that a pause (≈ 3 min) in the delivery of shockwaves (SWs) soon after the initiation of SW lithotripsy (SWL) is unnecessary for achieving a reduction in renal injury, if treatment is begun at a low power setting that generates low-amplitude SWs. Materials and methods: • Anaesthetised female pigs were assigned to one of three SWL treatment protocols that did not involve a pause in SW delivery of >10 s (2000 SWs at 24 kV; 100 SWs at 12 kV + ≈ 10-s pause + 2000 SWs at 24 kV; 500 SWs at 12 kV + ≈ 10-s pause + 2000 SWs at 24 kV). • All SWs were delivered at 120 SWs/min using an unmodified Dornier HM3 lithotripter. • Renal function was measured before and after SWL. • The kidneys were then processed for quantification of the SWL-induced haemorrhagic lesion. Values for lesion size were compared to previous data collected from pigs in which treatment included a 3-min pause in SW delivery. Results: • All SWL treatment protocols produced a similar degree of vasoconstriction (23-41% reduction in glomerular filtration rate and effective renal plasma flow) in the SW-treated kidney. • The mean renal lesion in pigs treated with 100 low-amplitude SWs delivered before the main dose of 2000 high-amplitude SWs (2.27% functional renal volume [FRV]) was statistically similar to that measured for pigs treated with 2000 SWs all at high-amplitude (3.29% FRV). • However, pigs treated with 500 low-amplitude SWs before the main SW dose had a significantly smaller lesion (0.44% FRV) that was comparable with the lesion in pigs from a previous study in which there was a 3-min pause in treatment separating a smaller initial dose of 100 low-amplitude SWs from the main dose of 2000 high-amplitude SWs (0.46% FRV). The time between the initiation of the low - and high-amplitude SWs was ≈ 4 min for these latter two groups compared with ≈ 1 min when there was negligible pause after the initial 100 low-amplitude SWs in the protocol. Conclusions: • Pig kidneys treated by SWL using a two-step low-to-high power ramping protocol were protected from injury with negligible pause between steps, provided the time between the initiation of low-amplitude SWs and switching to high-amplitude SWs was ≈ 4 min. • Comparison with results from previous studies shows that protection can be achieved using various step-wise treatment scenarios in which either the initial dose of SWs is delivered at low-amplitude for ≈ 4 min, or there is a definitive pause before resuming SW treatment at higher amplitude. • Thus, we conclude that renal protection can be achieved without instituting a pause in SWL treatment. It remains prudent to consider that renal protection depends on the acoustic and temporal properties of SWs administered at the beginning stages of a SWL ramping protocol, and that this may differ according to the lithotripter being used.
  • Loading...
    Thumbnail Image
    Item
    Percutaneous Renal Access: Surgical Factors Involved in the Acute Reduction of Renal Function
    (Mary Ann Liebert, Inc., 2016-02) Handa, Rajash K.; Johnson, Cynthia D.; Connors, Bret A.; Evan, Andrew P.; Lingeman, James E.; Liu, Ziyue; Department of Anatomy & Cell Biology, IU School of Medicine
    INTRODUCTION AND OBJECTIVE: Studies in patients and experimental animals have shown that percutaneous nephrolithotomy (PCNL) can acutely impair glomerular filtration and renal perfusion, but the factors contributing to this decline in renal function are unknown. The present study assessed the contribution of needle puncture of the kidney vs dilation of the needle tract to the acute decline in renal hemodynamic and tubular transport function associated with PCNL surgery. MATERIALS AND METHODS: Acute experiments were performed in three groups of anesthetized adult farm pigs: sham-percutaneous access (PERC), that is, no surgical procedure (n = 7); a single-needle stick to access the renal collecting system (n = 8); expansion of the single-needle access tract with a 30F NephroMax balloon dilator and insertion of a nephrostomy sheath (n = 10). The glomerular filtration rate (GFR), effective renal plasma flow (ERPF), and renal extraction of para-amino hippurate (EPAH, estimates tubular organic anion transporter [OAT] activity) were assessed before and 1 to 4.5 hours after sham-PERC or PERC surgical procedures. RESULTS: Overall, GFR responses were similar in all three groups. Sham-treated PERC pigs showed no significant change in ERPF over the experimental observation period, whereas a single-needle stick to access the renal collecting system resulted in renal vasoconstriction (∼30% reduction in ERPF, p < 0.05). Dilation of the single-needle access tract to create the nephrostomy did not lead to a further decline in ERPF. PERC surgical procedure-mediated renal vasoconstriction was most evident at the 1-hour posttreatment time point. A reduction in EPAH was only observed in pig kidneys with a nephrostomy. CONCLUSIONS: Needle puncture of the kidney for percutaneous access to the renal collecting system is the major driving force for the renal vasoconstriction observed after PCNL surgery, whereas creation of the nephrostomy appears to be largely responsible for decreasing tubular OAT activity.
  • «
  • 1 (current)
  • 2
  • »
About IU Indianapolis ScholarWorks
  • Accessibility
  • Privacy Notice
  • Copyright © 2025 The Trustees of Indiana University