Dual-Gated Volumetric Modulated Arc Therapy

dc.contributor.authorFahimian, Benjamin
dc.contributor.authorWu, Junqing
dc.contributor.authorWu, Huanmei
dc.contributor.authorGeneser, Sarah
dc.contributor.authorXing, Lei
dc.contributor.departmentDepartment of BioHealth Informatics, School of Informatics and Computingen_US
dc.date.accessioned2016-05-24T18:32:28Z
dc.date.available2016-05-24T18:32:28Z
dc.date.issued2014
dc.description.abstractBACKGROUND: Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging radiation therapy modality for treatment of tumors affected by respiratory motion. However, gating significantly prolongs the treatment time, as delivery is only activated during a single respiratory phase. To enhance the efficiency of gated VMAT delivery, a novel dual-gated VMAT (DG-VMAT) technique, in which delivery is executed at both exhale and inhale phases in a given arc rotation, is developed and experimentally evaluated. METHODS: Arc delivery at two phases is realized by sequentially interleaving control points consisting of MUs, MLC sequences, and angles of VMAT plans generated at the exhale and inhale phases. Dual-gated delivery is initiated when a respiration gating signal enters the exhale window; when the exhale delivery concludes, the beam turns off and the gantry rolls back to the starting position for the inhale window. The process is then repeated until both inhale and exhale arcs are fully delivered. DG-VMAT plan delivery accuracy was assessed using a pinpoint chamber and diode array phantom undergoing programmed motion. RESULTS: DG-VMAT delivery was experimentally implemented through custom XML scripting in Varian's TrueBeam™ STx Developer Mode. Relative to single gated delivery at exhale, the treatment time was improved by 95.5% for a sinusoidal breathing pattern. The pinpoint chamber dose measurement agreed with the calculated dose within 0.7%. For the DG-VMAT delivery, 97.5% of the diode array measurements passed the 3%/3 mm gamma criterion. CONCLUSIONS: The feasibility of DG-VMAT delivery scheme has been experimentally demonstrated for the first time. By leveraging the stability and natural pauses that occur at end-inspiration and end-exhalation, DG-VMAT provides a practical method for enhancing gated delivery efficiency by up to a factor of two.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationFahimian, B., Wu, J., Wu, H., Geneser, S., & Xing, L. (2014). Dual-gated volumetric modulated arc therapy. Radiation Oncology (London, England), 9, 209. http://doi.org/10.1186/1748-717X-9-209en_US
dc.identifier.issn1748-717Xen_US
dc.identifier.urihttps://hdl.handle.net/1805/9634
dc.language.isoen_USen_US
dc.publisherSpringer (Biomed Central Ltd.)en_US
dc.relation.isversionof10.1186/1748-717X-9-209en_US
dc.relation.journalRadiation Oncology (London, England)en_US
dc.rightsAttribution 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/
dc.sourcePMCen_US
dc.subjectNeoplasmsen_US
dc.subjectRadiotherapyen_US
dc.subjectRadiotherapy Planning, Computer-Assisteden_US
dc.subjectmethodsen_US
dc.subjectRadiotherapy, Intensity-Modulateden_US
dc.titleDual-Gated Volumetric Modulated Arc Therapyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
13014_2013_Article_1193.pdf
Size:
2.38 MB
Format:
Adobe Portable Document Format
Description:
Final published version
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: