Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes

dc.contributor.authorHu, Rongrong
dc.contributor.authorWang, Chenkun
dc.contributor.authorRacette, Lyne
dc.contributor.departmentOphthalmology, School of Medicineen_US
dc.date.accessioned2018-03-14T14:28:05Z
dc.date.available2018-03-14T14:28:05Z
dc.date.issued2017-05-18
dc.description.abstractBACKGROUND: Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. METHODS: Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. All eyes had glaucomatous optic neuropathy or ocular hypertension, but normal SAP and FDT results at baseline. The development of glaucomatous VF defects was defined as the presence of a cluster of ≥ 3 (less conservative) or ≥ 4 (more conservative) locations confirmed on ≥ 2 additional consecutive tests. Risk factors for the development of VF defects were analyzed by COX proportional hazard models. After conversion into common logarithmic units, the rates of change of global VF indices were fitted with linear mixed models. RESULTS: FDT detected more eyes that developed VF defects than SAP using the less conservative criterion, and no significant difference was observed using the more conservative criterion. For those eyes detected by both SAP and FDT, FDT detected the development of VF defects either earlier than SAP or simultaneously in most cases. Baseline structural measurements were not significantly associated with an increased risk for the development of glaucomatous VF defects on either SAP or FDT. Older age was significantly associated with the development of VF defects on FDT but not on SAP. Both SAP and FDT detected a progressing worsening trend of pattern standard deviation over time with a similar rate of change between these test types. CONCLUSIONS: Matrix FDT would be useful to monitor the onset of VF defects in glaucoma suspects and may outperform SAP in the early stage of glaucomatous VF damage.en_US
dc.identifier.citationHu, R., Wang, C., & Racette, L. (2017). Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes. PloS one, 12(5), e0178079. https://doi.org/10.1371/journal.pone.0178079en_US
dc.identifier.urihttps://hdl.handle.net/1805/15506
dc.language.isoen_USen_US
dc.publisherPLOSen_US
dc.relation.isversionof10.1371/journal.pone.0178079en_US
dc.relation.journalPLoS ONEen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/
dc.sourcePMCen_US
dc.subjectAge Factorsen_US
dc.subjectAgeden_US
dc.subjectGlaucomaen_US
dc.subjectOcular Hypertensionen_US
dc.subjectProportional Hazards Modelsen_US
dc.titleComparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyesen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pone.0178079.pdf
Size:
903.56 KB
Format:
Adobe Portable Document Format
Description:
Research Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: