Utility of pre-procedural [99mTc]TcMAA SPECT/CT Multicompartment Dosimetry for Treatment Planning of 90Y Glass microspheres in patients with Hepatocellular Carcinoma: comparison of anatomic versus [99mTc]TcMAA-based Segmentation

Date
2025
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Springer
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Purpose: Pre-treatment [99mTc]TcMAA-based radioembolization treatment planning using multicompartment dosimetry involves the definition of the tumor and normal tissue compartments and calculation of the prescribed absorbed doses. The aim was to compare the real-world utility of anatomic and [99mTc]TcMAA-based segmentation of tumor and normal tissue compartments.

Materials and methods: Included patients had HCC treated by glass [90Y]yttrium microspheres, ≥ 1 tumor, ≥ 3 cm diameter and [99mTc]TcMAA SPECT/CT imaging before treatment. Segmentation was performed retrospectively using dedicated dosimetry software: (1) anatomic (diagnostic CT/MRI-based), and (2) [99mTc]TcMAA threshold-based (i.e., using an activity-isocontour threshold). CT/MRI was co-registered with [99mTc]TcMAA SPECT/CT. Logistic regression and Cox regression, respectively, were used to evaluate relationships between total perfused tumor absorbed dose (TAD) and objective response rate (ORR) and overall survival (OS). In a subset-analysis pre- and post-treatment dosimetry were compared using Bland-Altman analysis and Pearson's correlation coefficient.

Results: A total of 209 patients were enrolled. Total perfused tumor and normal tissue volumes were larger when using anatomic versus [99mTc]TcMAA threshold segmentation, resulting in lower absorbed doses. mRECIST ORR was higher with increasing total perfused TAD (odds ratio per 100 Gy TAD increase was 1.22 (95% CI: 1.01-1.49; p = 0.044) for anatomic and 1.19 (95% CI: 1.04-1.37; p = 0.012) for [99mTc]TcMAA threshold segmentation. Higher total perfused TAD was associated with improved OS (hazard ratio per 100 Gy TAD increase was 0.826 (95% CI: 0.714-0.954; p = 0.009) and 0.847 (95% CI: 0.765-0.936; p = 0.001) for anatomic and [99mTc]TcMAA threshold segmentation, respectively). For pre- vs. post-treatment dosimetry comparison, the average bias for total perfused TAD was + 11.5 Gy (95% limits of agreement: -227.0 to 250.0) with a strong positive correlation (Pearson's correlation coefficient = 0.80).

Conclusion: Real-world data support [99mTc]TcMAA imaging to estimate absorbed doses prior to treatment of HCC with glass [90Y]yttrium microspheres. Both anatomic and [99mTc]TcMAA threshold methods were suitable for treatment planning.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Lam M, Garin E, Haste P, et al. Utility of pre-procedural [99mTc]TcMAA SPECT/CT Multicompartment Dosimetry for Treatment Planning of 90Y Glass microspheres in patients with Hepatocellular Carcinoma: comparison of anatomic versus [99mTc]TcMAA-based Segmentation. Eur J Nucl Med Mol Imaging. 2025;52(2):744-755. doi:10.1007/s00259-024-06920-6
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
European Journal of Nuclear Medicine and Molecular Imaging
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}