Comparing the Clinical Utility and Diagnostic Performance of CSF P-Tau181, P-Tau217, and P-Tau231 Assays

Date
2021
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wolters Kluwer
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Background and objectives: Phosphorylated tau (p-tau) in CSF is considered an important biomarker in Alzheimer disease (AD) and has been incorporated in recent diagnostic criteria. Several variants exist, including p-tau at threonines 181 (p-tau181), 217 (p-tau217), and 231 (p-tau231). However, no studies have compared their diagnostic performance or association to β-amyloid (Aβ) and tau-PET. Understanding which p-tau variant to use remains an important yet answered question. We aimed to compare the diagnostic accuracy of p-tau181, p-tau217, and p-tau231 in CSF for AD and their association with Aβ and tau-PET.

Methods: A total of 629 participants in the Swedish BioFINDER-2 study were included (cognitively unimpaired, n = 334; Aβ-positive mild cognitive impairment, n = 84; AD dementia, n = 119; and non-AD disorders, n = 92). In addition to p-tau181 and p-tau217 measured using assays with the same detector antibodies from Eli Lilly (p-tau181Lilly, p-tau217Lilly) and p-tau231, we also included p-tau181 measurements from 2 commonly used assays (Innotest and Elecsys).

Results: Although all p-tau variants increased across the AD continuum, p-tau217Lilly showed the greatest dynamic range (13-fold increase vs 1.9-5.4-fold increase for other p-tau variants for AD dementia vs non-AD). P-Tau217Lilly showed stronger correlations with Aβ- and tau-PET (p < 0.0001). P-Tau217Lilly exhibited higher accuracy than other p-tau variants for separating AD dementia from non-AD (area under the curve [AUC], 0.98 vs 0.88 [p < 0.0001] - 0.96 [p < 0.05]) and for identifying Aβ-PET (AUC, 0.86 vs 0.74 [p < 0.0001] and 0.83 [p < 0.001]) and tau-PET positivity (AUC, 0.94 vs 0.80-0.92, p < 0.0001). Finally, p-Tau181Lilly generally performed better than the other p-tau181 assays (e.g., AD dementia vs non-AD, AUC, 0.96 vs 0.88 [p-tau181Innotest] and 0.89 [p-tau181Elecsys]; p < 0.0001).

Discussion: CSF p-tau217Lilly seems to be more useful than other included p-tau assays in the workup of AD. Varied results across p-tau181 assays highlights the importance of anti-tau antibodies for biomarker performance.

Classification of evidence: This study provides Class II evidence that p-tau217 provides higher diagnostic accuracy for diagnosis of AD dementia than p-tau181 or p-tau231.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Leuzy A, Janelidze S, Mattsson-Carlgren N, et al. Comparing the Clinical Utility and Diagnostic Performance of CSF P-Tau181, P-Tau217, and P-Tau231 Assays. Neurology. 2021;97(17):e1681-e1694. doi:10.1212/WNL.0000000000012727
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Neurology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}