Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study

dc.contributor.authorYadav, Poonam
dc.contributor.authorDesRosiers, Colleen M.
dc.contributor.authorMitra, Raj K.
dc.contributor.authorSrivastava, Shiv P.
dc.contributor.authorDas, Indra J.
dc.contributor.departmentRadiation Oncology, School of Medicine
dc.date.accessioned2023-10-25T18:02:01Z
dc.date.available2023-10-25T18:02:01Z
dc.date.issued2023-01-23
dc.description.abstractDose-calculation algorithms are critical for radiation treatment outcomes that vary among treatment planning systems (TPS). Modern algorithms use sophisticated radiation transport calculation with detailed three-dimensional beam modeling to provide accurate doses, especially in heterogeneous medium and small fields used in IMRT/SBRT. While the dosimetric accuracy in heterogeneous mediums (lung) is qualitatively known, the accuracy is unknown. The aim of this work is to analyze the calculated dose in lung patients and compare the validity of dose-calculation algorithms by measurements in a low-Z phantom for two main classes of algorithms: type A (pencil beam) and type B (collapse cone). The CT scans with volumes (target and organs at risk, OARs) of a lung patient and a phantom build to replicate the human lung data were sent to nine institutions for planning. Doses at different depths and field sizes were measured in the phantom with and without inhomogeneity correction across multiple institutions to understand the impact of clinically used dose algorithms. Wide dosimetric variations were observed in target and OAR coverage in patient plans. The correction factor for collapsed cone algorithms was less than pencil beam algorithms in the small fields used in SBRT. The pencil beam showed ≈70% variations between measured and calculated correction factors for various field sizes and depths. For large field sizes the trends of both types of algorithms were similar. The differences in measured versus calculated dose for type-B algorithms were within ±10%. Significant variations in the target and OARs were observed among various TPS. The results suggest that the pencil beam algorithm does not provide an accurate dose and should not be considered with small fields (IMRT/SBRT). Type-B collapsed-cone algorithms provide better agreement with measurements, but still vary among various systems.
dc.eprint.versionFinal published version
dc.identifier.citationYadav P, DesRosiers CM, Mitra RK, Srivastava SP, Das IJ. Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study. J Clin Med. 2023;12(3):906. Published 2023 Jan 23. doi:10.3390/jcm12030906
dc.identifier.urihttps://hdl.handle.net/1805/36673
dc.language.isoen_US
dc.publisherMDPI
dc.relation.isversionof10.3390/jcm12030906
dc.relation.journalJournal of Clinical Medicine
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.sourcePMC
dc.subjectLung cancer
dc.subjectIMRT
dc.subjectHeterogeneity correction
dc.subjectDose calculation
dc.subjectAlgorithm
dc.titleVariability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jcm-12-00906.pdf
Size:
25.17 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: