Abstract

Background Although ceramic-on-ceramic bearings for total hip arthroplasty (THA) show promising results in terms of bearing-surface wear, fracture of the bearing, insertional chips, and squeaking remain a concern. Questions/purposes Our primary objective of this report was to determine overall survivorship of a titanium- encased ceramic-on-ceramic bearing couple. Our secondary objectives were to evaluate for ceramic fracture, insertional chips, osteolysis, and device squeaking. Methods Six surgeons at six institutions implanted 194 patients (209 hips) with an average age of 52 years with cementless hips and alumina ceramic bearings. One hun- dred thirty-seven patients (146 hips) have 10-year followup (70%). We determined Kaplan-Meier survivorship of the bearing surface and implant system and collected radio- graphic and clinical data to evaluate for osteolysis and squeaking. Results Survivorship using revision for any reason as the end point was 97% at 10 years and survivorship end point bearing surface failure or aseptic loosening of 99%. There was one ceramic insert fracture (0.5%), there were no insertional chips, there was no visible osteolysis on AP and lateral radiographs, and there was a 1% patient- self-reported incidence of squeaking at the last clinical followup. Six hips underwent revision (3.7%). Conclusions Ceramic bearings for THA with a titanium- encased insert have high survivorship at 10 years followup and a fracture risk of 0.5%. We found at last followup on routine radiographs no evidence of osteolysis, and no patient has been revised for squeaking or has reported dissatisfaction with the clinical result because of noise. Level of Evidence Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
D’Antonio, J. A., Capello, W. N., & Naughton, M. (2014). High Survivorship With a Titanium-encased Alumina Ceramic Bearing for Total Hip Arthroplasty. Clinical Orthopaedics and Related Research, 472(2), 611–616. http://doi.org/10.1007/s11999-013-2943-5
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Clinical Orthopaedics and Related Research
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}