Detection and analyzing plane of non-cavitated approximal caries by cross-polarized optical coherence tomography (CP-OCT)

Date
2021-07
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Objective The objective was to assess the detection ability and the effect of analyzing plane of CP-OCT for non-cavitated approximal caries.

Methods Thirty human extracted premolars were selected based on micro-computed tomography [μ-CT: μ- CT = 0: sound (n = 12), μ-CT = 1/2: caries into outer-/inner-half of enamel (n = 6 each), μ-CT = 3: caries into outer one-third of dentine (n = 6)]. Teeth were mounted in a custommade device to simulate approximal contact, and scanned from the marginal ridge above the contact area. CP-OCT images were analyzed by deepest caries extension from horizontal and coronal planes, and repeated 48-hrs later. Sensitivity, specificity,percent correct, area under the ROC curve (Az), intra-examiner repeatability and correlation with μ-CT were determined.

Results Sensitivity/specificity/Az for Horizontalplane, Coronal-plane, and Deepest from both planes were 94percent/58percent/0.76,81percent/100percent/0.90, and 94 %/58 %/0.82. Coronal-plane had significantly higher specificity than Horizontal-plane and Deepest (p = 0.004) but Horizontal-plane and Deepest were not different (p = 1.00). Horizontal-plane had significantly lower Az than Deepest (p = 0.048), but Coronal-plane was not different than Horizontal-plane (p = 0.07) or Deepest (p = 0.20). Correlation coefficients were Horizontal-plane (0.53, p < 0.001), Coronal-plane (0.84, p < 0.001), and Deepest (0.66, p < 0.001).

Conclusion Within the limitations of this study, CP-OCT could be used to detect non-cavitated approximal caries. Analysis using the Coronal-plane is superior to the Horizontal-plane. Clinical Significance: It is challenging to detect non-cavitated approximal caries clinically due to the adjacent tooth. CP-OCT is a nondestructive, no ionized-radiation caries detection technique. CP-OCT seems suitable to detect non-cavitated approximal caries and observing the Coronal-plane appears better than Horizontal-plane.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Xing, H., Eckert, G. J., & Ando, M. (2021). Detection and analyzing plane of non-cavitated approximal caries by cross-polarized optical coherence tomography (CP-OCT). Journal of Dentistry, 110, 103679. https://doi.org/10.1016/j.jdent.2021.103679
ISSN
0300-5712
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Dentistry
Rights
Publisher Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}