Radiation-Induced Lymphopenia Risks of Photon Versus Proton Therapy for Esophageal Cancer Patients

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2021-04-07
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Purpose: To assess possible differences in radiation-induced lymphocyte depletion for esophageal cancer patients being treated with the following 3 treatment modalities: intensity-modulated radiation therapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT).

Methods and materials: We used 2 prediction models to estimate lymphocyte depletion based on dose distributions. Model I used a piecewise linear relationship between lymphocyte survival and voxel-by-voxel dose. Model II assumes that lymphocytes deplete exponentially as a function of total delivered dose. The models can be fitted using the weekly absolute lymphocyte counts measurements collected throughout treatment. We randomly selected 45 esophageal cancer patients treated with IMRT, PSPT, or IMPT at our institution (15 per modality) to demonstrate the fitness of the 2 models. A different group of 10 esophageal cancer patients who had received PSPT were included in this study of in silico simulations of multiple modalities. One IMRT and one IMPT plan were created, using our standards of practice for each modality, as competing plans to the existing PSPT plan for each patient. We fitted the models by PSPT plans used in treatment and predicted absolute lymphocyte counts for IMRT and IMPT plans.

Results: Model validation on each modality group of patients showed good agreement between measured and predicted absolute lymphocyte counts nadirs with mean squared errors from 0.003 to 0.023 among the modalities and models. In the simulation study of IMRT and IMPT on the 10 PSPT patients, the average predicted absolute lymphocyte count (ALC) nadirs were 0.27, 0.35, and 0.37 K/μL after IMRT, PSPT, and IMPT treatments using Model I, respectively, and 0.14, 0.22, and 0.33 K/μL using Model II.

Conclusions: Proton plans carried a lower predicted risk of lymphopenia after the treatment course than did photon plans. Moreover, IMPT plans outperformed PSPT in terms of predicted lymphocyte preservation.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Ebrahimi S, Lim G, Liu A, et al. Radiation-Induced Lymphopenia Risks of Photon Versus Proton Therapy for Esophageal Cancer Patients. Int J Part Ther. 2021;8(2):17-27. Published 2021 Apr 7. doi:10.14338/IJPT-20-00086
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
International Journal of Particle Therapy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}