Functional liver-image guided hepatic therapy (FLIGHT): A technique to maximize hepatic functional reserve

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2020-06
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Introduction: Radiation planning approaches for liver radiation often do not consider the regional variation that can exist in liver function. This study dosimetrically compares functional liver image-guided hepatic therapy (FLIGHT) to standard stereotactic body radiation therapy (SBRT) plans. In the FLIGHT plans, functional data from hepatobiliary iminodiacetic acid (HIDA) single photon emission computed tomography (SPECT) scans serve as a road map to guide beam arrangement. While meeting the same target volume coverage, plans are optimized to reduce dose to high-functioning liver. Materials and Methods: The study included 10 patients with hepatocellular carcinoma (HCC) with baseline HIDA SPECT imaging. Standard SBRT plans which did not systematically incorporate these scans had previously been completed on all 10 plans. Retrospectively, FLIGHT plans were created based on the use of contours of relative liver function from the HIDA SPECT as avoidance structures. Resulting dose to each relative functional liver structure was examined and compared qualitatively and using Wilcoxin rank-sum tests. Target coverage, doses to organs at risk (OARs), conformity index (CI), and gradient index (GI) were also evaluated. Results: While maintaining the same target coverage, FLIGHT plans reduced the mean dose to the high functioning liver by a median of 3.0 Gy (range 0.7 to 4.6 Gy), which represented a 31.4% mean reduction compared to standard planning. FLIGHT plans reduced the volume of high functioning liver receiving 15 Gy by a mean of 59.3 cc (range 7 to 170 cc), for a mean reduction of 41.9%. The mean dose to areas of liver function defined by 25% to 100% and 50% to 100% maximum was reduced with FLIGHT from 10.5 Gy to 8.5 Gy and from 10.5 Gy to 7.5 Gy, respectively ( p < 0.005 for both comparisons). The FLIGHT plans’ mean CI and GI did not differ significantly from the standard plans’ ( p = 0.721 and 0.169, respectively). Conclusion: FLIGHT SBRT allows for field design and plan optimization individualized to a patient's baseline regional liver function to maximize hepatic functional reserve. This personalized approach is achieved without compromising target coverage or OAR sparing.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Furukawa, Y., Long, D. E., & Ellsworth, S. G. (2020). Functional liver-image guided hepatic therapy (FLIGHT): A technique to maximize hepatic functional reserve. Medical Dosimetry, 45(2), P117-120. https://doi.org/10.1016/j.meddos.2019.07.007
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Medical Dosimetry
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}