Utilization Rates of Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death: A 2012 Calculation for a Midwestern Health Referral Region
Date
Language
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
Background Utilization rates (URs) for implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden cardiac death (PPSCD) are lacking in the community.
Objective To establish the ICD UR in central Indiana.
Methods A query run on two hospitals in a health information exchange database in Indianapolis identified patients between 2011 and 2012 with left ventricular ejection fraction (EF) ≤0.35. ICD-eligibility and utilization were determined from chart review.
Results We identified 1,863 patients with at least one low-EF study. Two cohorts were analyzed: 1,672 patients without, and 191 patients with, ICD-9-CM procedure code 37.94 for ICD placement. We manually reviewed a stratified (by hospital) random sample of 300 patients from the no-ICD procedure code cohort and found that 48 (16%) had no ICD but had class I indications for ICD. Eight of 300 (2.7%) actually had ICD implantation for PPSCD. Review of all 191 patients in the ICD procedure code cohort identified 70 with ICD implantation for PPSCD. The ICD UR (ratio between patients with ICD for PPSCD and all with indication) was 38% overall (95% CI 28–49%). URs were 48% for males (95% CI 34–61%), 21% for females (95% CI 16–26%, p=0.0002 vs males), 40% for whites (95% CI 27–53%), and 37% for blacks (95% CI 28–46%, p=0.66 vs whites).
Conclusions The ICD UR is 38% among patients meeting Class I indications, suggesting further opportunities to improve guideline compliance. Furthermore, this study illustrates limitations in calculating ICD UR using large electronic repositories without hands-on chart review.