Unusual Case of Pump Thrombosis in LVAD Patient with COVID-19 — Diagnostic Challenges

dc.contributor.authorFrick, William H.
dc.contributor.authorMallory, Ryan D.
dc.contributor.authorGuglin, Maya
dc.contributor.authorAnderson, Eve
dc.contributor.authorLushin, Erin L.
dc.contributor.authorVivo, Rey P.
dc.contributor.authorSaleem, Kashif
dc.contributor.authorRao, Roopa A.
dc.contributor.departmentMedicine, School of Medicineen_US
dc.date.accessioned2020-11-13T00:08:21Z
dc.date.available2020-11-13T00:08:21Z
dc.date.issued2020-09-18
dc.description.abstractWe present the first reported case of left ventricular assist device (LVAD) pump thrombosis in the setting of the coronavirus pandemic. We describe the clinical features of the case which helped to differentiate coronavirus disease 19 (COVID-19)from LVAD pump thrombosis. The patient is 56-year-old female supported by destination LVAD therapy. She was originally implanted with a HeartMate II device in 2015 and underwent two pump exchanges in 2017 and 2019 for pump thrombosis, despite medication adherence. Shortly after routine lab work revealed near doubling of her lactate dehydrogenase (LDH) levels, she tested positive for COVID-19. She then developed power spikes and symptomatic heart failure, which prompted hospital admission. An initial computed tomography (CT) scan showed bilateral ground glass opacities, but repeat testing was negative for COVID-19. Her LVAD pump thrombosis was treated with aspirin, unfractionated heparin, and cangrelor, which was guided by thromboelastogram. Over several weeks, her LDH returned to baseline, and she was transitioned from cangrelor to ticagrelor and from heparin to warfarin. A repeat CT scan after several days of IV diuresis showed resolution of the ground glass opacities.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationFrick, W. H., Mallory, R. D., Guglin, M., Anderson, E., Lushin, E. L., Vivo, R. P., Saleem, K., & Rao, R. A. (2020). Unusual Case of Pump Thrombosis in LVAD Patient with COVID-19—Diagnostic Challenges. The VAD Journal, 6(2), 8.en_US
dc.identifier.urihttps://hdl.handle.net/1805/24382
dc.language.isoen_USen_US
dc.publisherGill Heart Institute, University of Kentuckyen_US
dc.relation.journalVAD Journal: The Journal of Mechanical Assisted Circulation and Heart Failureen_US
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.sourcePublisheren_US
dc.subjectCOVID-19en_US
dc.subjectLeft Ventricular Assist Device (LVAD)en_US
dc.subjectPump Thrombosis (PT)en_US
dc.subjectCase Studyen_US
dc.titleUnusual Case of Pump Thrombosis in LVAD Patient with COVID-19 — Diagnostic Challengesen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Frick2020Unusual.pdf
Size:
586.29 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: