Pitching single-focus confocal data analysis one photon at a time with Bayesian nonparametrics

dc.contributor.authorTavakoli, Meysam
dc.contributor.authorJazani, Sina
dc.contributor.authorSgouralis, Ioannis
dc.contributor.authorShafraz, Omer M.
dc.contributor.authorSivasankar, Sanjeevi
dc.contributor.authorDonaphon, Bryan
dc.contributor.authorLevitus, Marcia
dc.contributor.authorPressé, Steve
dc.contributor.departmentPhysics, School of Scienceen_US
dc.date.accessioned2023-03-09T14:46:18Z
dc.date.available2023-03-09T14:46:18Z
dc.date.issued2020
dc.description.abstractFluorescence time traces are used to report on dynamical properties of molecules. The basic unit of information in these traces is the arrival time of individual photons, which carry instantaneous information from the molecule, from which they are emitted, to the detector on timescales as fast as microseconds. Thus, it is theoretically possible to monitor molecular dynamics at such timescales from traces containing only a sufficient number of photon arrivals. In practice, however, traces are stochastic and in order to deduce dynamical information through traditional means-such as fluorescence correlation spectroscopy (FCS) and related techniques-they are collected and temporally autocorrelated over several minutes. So far, it has been impossible to analyze dynamical properties of molecules on timescales approaching data acquisition without collecting long traces under the strong assumption of stationarity of the process under observation or assumptions required for the analytic derivation of a correlation function. To avoid these assumptions, we would otherwise need to estimate the instantaneous number of molecules emitting photons and their positions within the confocal volume. As the number of molecules in a typical experiment is unknown, this problem demands that we abandon the conventional analysis paradigm. Here, we exploit Bayesian nonparametrics that allow us to obtain, in a principled fashion, estimates of the same quantities as FCS but from the direct analysis of traces of photon arrivals that are significantly smaller in size, or total duration, than those required by FCS.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationTavakoli M, Jazani S, Sgouralis I, et al. Pitching single-focus confocal data analysis one photon at a time with Bayesian nonparametrics. Phys Rev X. 2020;10(1):011021. doi:10.1103/physrevx.10.011021en_US
dc.identifier.urihttps://hdl.handle.net/1805/31759
dc.language.isoen_USen_US
dc.publisherAmerican Physical Societyen_US
dc.relation.isversionof10.1103/physrevx.10.011021en_US
dc.relation.journalPhysical Review Xen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectSingle photon detectionen_US
dc.subjectSpectroscopyen_US
dc.subjectConfocal microscopyen_US
dc.subjectBayesian nonparametricsen_US
dc.titlePitching single-focus confocal data analysis one photon at a time with Bayesian nonparametricsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1613897.pdf
Size:
4.42 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: