Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

dc.contributor.authorHamada, Yusuke
dc.contributor.authorPrabhu, Srividya
dc.contributor.authorJohn, Vanchit
dc.contributor.departmentDepartment of Periodontics & Allied Dental Programsen_US
dc.date.accessioned2017-08-16T17:31:43Z
dc.date.available2017-08-16T17:31:43Z
dc.date.issued2016
dc.description.abstractAs implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationHamada, Y., Prabhu, S., & John, V. (2016). Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis. Case Reports in Dentistry, 2016, 1746961. http://doi.org/10.1155/2016/1746961en_US
dc.identifier.issn2090-6447en_US
dc.identifier.urihttps://hdl.handle.net/1805/13842
dc.language.isoen_USen_US
dc.publisherHindawi Publishing Corporationen_US
dc.relation.isversionof10.1155/2016/1746961en_US
dc.relation.journalCase Reports in Dentistryen_US
dc.rightsAttribution 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/
dc.sourcePMCen_US
dc.subjectSurgeryen_US
dc.subjectTransplants & implantsen_US
dc.subjectMedical imagingen_US
dc.subjectpathologyen_US
dc.subjectPatientsen_US
dc.subjectDefectsen_US
dc.subjectTeethen_US
dc.subjectDentistryen_US
dc.subjectDentistsen_US
dc.titleTreatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitisen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CRID2016-1746961.pdf
Size:
2.52 MB
Format:
Adobe Portable Document Format
Description:
Final published version
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: