Evaluation of variable flip angle, MOLLI, SASHA, and IR-SNAPSHOT pulse sequences for T1 relaxometry and extracellular volume imaging of the pancreas and liver

dc.contributor.authorTirkes, Temel
dc.contributor.authorZhao, Xuandong
dc.contributor.authorLin, Chen
dc.contributor.authorStuckey, Alex Jordan
dc.contributor.authorLi, Liang
dc.contributor.authorGiri, Shivriman
dc.contributor.authorNickel, Dominik
dc.contributor.departmentRadiology and Imaging Sciences, School of Medicineen_US
dc.date.accessioned2021-08-02T02:51:15Z
dc.date.available2021-08-02T02:51:15Z
dc.date.issued2019-06-04
dc.description.abstractPurpose Compare four T1 mapping pulse sequences for T1 relaxometry and extracellular volume (ECV) fraction of the pancreas and liver Materials and Methods In vitro phase of this prospective study was performed on a T1 phantom, followed by imaging twenty-two patients. Variable flip angle (VFA), modified Look-Locker inversion recovery (MOLLI), prototype saturation recovery single-shot acquisition (SASHA), and prototype inversion recovery (IR-SNAPSHOT) pulse sequences were used to obtain T1 and ECV maps on the same 1.5T MR scanner using the same imaging protocol. Results In vitro tests showed almost perfect precision of MOLLI (ρc=0.9998), SASHA (ρc=0.9985) and IR-SNAPSHOT (ρc=0.9976) while VFA showed relatively less, however substantial precision (ρc=0.9862). Results of patient scans showed similar ECV fraction of the liver (p=0.08), pancreas (p=0.43), and T1 of the liver (p=0.08) with all pulse sequences. T1 of the pancreas with MOLLI, SASHA and IR-SNAPSHOT were statistically similar (p>0.05). Conclusion MOLLI, SASHA and IR-SNAPSHOT provided almost perfect in vitro precision and similar T1 during in vivo scans. Similar ECV fractions of the liver and pancreas were obtained with all sequences. More refinement of pulse sequences to provide sufficient spatial coverage in one breath hold together with high precision would be desirable in abdominal imaging.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationTirkes, T., Zhao, X., Lin, C., Stuckey, A. J., Li, L., Giri, S., & Nickel, D. (2019). Evaluation of variable flip angle, MOLLI, SASHA, and IR-SNAPSHOT pulse sequences for T1 relaxometry and extracellular volume imaging of the pancreas and liver. Magnetic Resonance Materials in Physics, Biology and Medicine, 32(5), 559–566. https://doi.org/10.1007/s10334-019-00762-2en_US
dc.identifier.issn1352-8661en_US
dc.identifier.urihttps://hdl.handle.net/1805/26321
dc.language.isoen_USen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1007/s10334-019-00762-2en_US
dc.relation.journalMagnetic Resonance Materials in Physics, Biology and Medicineen_US
dc.sourcePMCen_US
dc.subjectMagnetic Resonance Imagingen_US
dc.subjectQuantitative Imagingen_US
dc.subjectT1 mappingen_US
dc.subjectExtracellular matrixen_US
dc.subjectLiveren_US
dc.subjectPancreasen_US
dc.titleEvaluation of variable flip angle, MOLLI, SASHA, and IR-SNAPSHOT pulse sequences for T1 relaxometry and extracellular volume imaging of the pancreas and liveren_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1039024.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:
Author's manuscript
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: