Variation in extubation failure rates after neonatal congenital heart surgery across Pediatric Cardiac Critical Care Consortium hospitals

Date
2017-06
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

OBJECTIVE:

In a multicenter cohort of neonates recovering from cardiac surgery, we sought to describe the epidemiology of extubation failure and its variability across centers, identify risk factors, and determine its impact on outcomes. METHODS:

We analyzed prospectively collected clinical registry data on all neonates undergoing cardiac surgery in the Pediatric Cardiac Critical Care Consortium database from October 2013 to July 2015. Extubation failure was defined as reintubation less than 72 hours after the first planned extubation. Risk factors were identified using multivariable logistic regression with generalized estimating equations to account for within-center correlation. RESULTS:

The cohort included 899 neonates from 14 Pediatric Cardiac Critical Care Consortium centers; 14% were premature, 20% had genetic abnormalities, 18% had major extracardiac anomalies, and 74% underwent surgery with cardiopulmonary bypass. Extubation failure occurred in 103 neonates (11%), within 24 hours in 61%. Unadjusted rates of extubation failure ranged from 5% to 22% across centers; this variability was unchanged after adjusting for procedural complexity and airway anomaly. After multivariable analysis, only airway anomaly was identified as an independent risk factor for extubation failure (odds ratio, 3.1; 95% confidence interval, 1.4-6.7; P = .01). Neonates who failed extubation had a greater median postoperative length of stay (33 vs 23 days, P < .001) and in-hospital mortality (8% vs 2%, P = .002). CONCLUSIONS:

This multicenter study showed that 11% of neonates recovering from cardiac surgery fail initial postoperative extubation. Only congenital airway anomaly was independently associated with extubation failure. We observed a 4-fold variation in extubation failure rates across hospitals, suggesting a role for collaborative quality improvement to optimize outcomes.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Benneyworth, B. D., Mastropietro, C. W., Graham, E. M., Klugman, D., Costello, J. M., Zhang, W., & Gaies, M. (2017). Variation in extubation failure rates after neonatal congenital heart surgery across Pediatric Cardiac Critical Care Consortium hospitals. The Journal of thoracic and cardiovascular surgery, 153(6), 1519-1526.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Thoracic and Cardiovascular Surgery
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at