Innovative Use of High-Fidelity Lung Simulators to Test a Ventilator Splitter Device

dc.contributor.authorBoyer, Tanna J.
dc.contributor.authorMitchell, Sally A.
dc.contributor.authorCartwright, Johnny F.
dc.contributor.authorAhmed, Rami A.
dc.contributor.departmentAnesthesia, School of Medicineen_US
dc.date.accessioned2020-11-09T20:57:04Z
dc.date.available2020-11-09T20:57:04Z
dc.date.issued2020-06-02
dc.descriptionThis article is made available for unrestricted research re-use and secondary analysis in any form or be any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.en_US
dc.description.abstractThe coronavirus disease 2019 (COVID-19) pandemic has rapidly exposed health care system inadequacies. Hospital ventilator shortages in Italy compelled US physicians to consider cre-ative solutions, such as using Y-pieces or T-pieces, to preclude the need to make decisions of life or death based on medical equipment availability. We add to current knowledge and testing capacity for ventilator splitters by reporting the ability to examine the functionality of ventilator splitters by using 2 high-fidelity lung simulators. Data obtained by the high-fidelity lung simula-tors included: tidal volume, respiratory rate, minute ventilation, peak inspiratory pressure, peak plateau pressure, and positive end-expiratory pressure.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationBoyer, T. J., Mitchell, S. A., Cartwright, J. F., & Ahmed, R. A. (2020). Innovative Use of High-Fidelity Lung Simulators to Test a Ventilator Splitter Device. A&A Practice, 14(8). https://doi.org/10.1213/XAA.0000000000001253en_US
dc.identifier.issn2575-3126en_US
dc.identifier.urihttps://hdl.handle.net/1805/24355
dc.language.isoen_USen_US
dc.publisherWolters Kluweren_US
dc.relation.isversionof10.1213/XAA.0000000000001253en_US
dc.relation.journalA&A Practiceen_US
dc.rightsPublic Health Emergencyen_US
dc.sourcePMCen_US
dc.subjectCOVID-19en_US
dc.subjectVentilatoren_US
dc.subjectVentilator Splitteren_US
dc.subjectLungsen_US
dc.subjectSimulatorsen_US
dc.titleInnovative Use of High-Fidelity Lung Simulators to Test a Ventilator Splitter Deviceen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Boyer2020Innovative.pdf
Size:
775.77 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: