Optimisation of recovery protocols for double-base smokeless powder residues analysed by total vaporisation (TV) SPME/GC-MS

dc.contributor.authorSauzier, Georgina
dc.contributor.authorBors, Dana
dc.contributor.authorAsh, Jordan
dc.contributor.authorGoodpaster, John V.
dc.contributor.authorLewis, Simon W.
dc.contributor.departmentChemistry and Chemical Biology, School of Scienceen_US
dc.date.accessioned2017-12-14T15:02:19Z
dc.date.available2017-12-14T15:02:19Z
dc.date.issued2016-09
dc.description.abstractThe investigation of explosive events requires appropriate evidential protocols to recover and preserve residues from the scene. In this study, a central composite design was used to determine statistically validated optimum recovery parameters for double-base smokeless powder residues on steel, analysed using total vaporisation (TV) SPME/GC-MS. It was found that maximum recovery was obtained using isopropanol-wetted swabs stored under refrigerated conditions, then extracted for 15 min into acetone on the same day as sample collection. These parameters were applied to the recovery of post-blast residues deposited on steel witness surfaces following a PVC pipe bomb detonation, resulting in detection of all target components across the majority of samples. Higher overall recoveries were obtained from plates facing the sides of the device, consistent with the point of first failure occurring in the pipe body as observed in previous studies. The methodology employed here may be readily applied to a variety of other explosive compounds, and thus assist in establishing ‘best practice’ procedures for explosive investigations.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationSauzier, G., Bors, D., Ash, J., Goodpaster, J. V., & Lewis, S. W. (2016). Optimisation of recovery protocols for double-base smokeless powder residues analysed by total vaporisation (TV) SPME/GC-MS. Talanta, 158, 368–374. https://doi.org/10.1016/j.talanta.2016.04.048en_US
dc.identifier.urihttps://hdl.handle.net/1805/14808
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.talanta.2016.04.048en_US
dc.relation.journalTalantaen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectdouble-base smokeless powderen_US
dc.subjecttotal vaporizationen_US
dc.subjectrecovery protocolsen_US
dc.titleOptimisation of recovery protocols for double-base smokeless powder residues analysed by total vaporisation (TV) SPME/GC-MSen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sauzier_2017_optimisation.pdf
Size:
546.79 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: