Effects of shade and thickness on the translucency parameter of anatomic-contour zirconia, transmitted light intensity, and degree of conversion of the resin cement

Date
2023-01
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Statement of problem Anatomic-contour zirconia prostheses are usually cemented with resin cement. However, information regarding the effects of the zirconia shade and thicknesses on the translucency of the prosthesis, the intensity of the transmitted light beneath the prosthesis, and the subsequent degree of conversion in the resin cement is sparse. Purpose The purpose of this in vitro study was to investigate the translucency parameter in 3 anatomic-contour zirconia specimens of 2 shades at 5 different thicknesses and to investigate the transmitted light intensity and degree of conversion of the resin cement beneath the ceramic specimens by using a traditional zirconia and a lithium disilicate glass ceramic as controls. Material and methods Ceramic specimens from 1 anatomic-contour zirconia in a generic shade (CAP FZ) and 2 anatomic-contour zirconias in A2 shade (Zirlux and Luxisse) were used. Lithium disilicate in HT A2 shade (IPS e.max CAD) and traditional zirconia in a generic shade (CAP QZ) were used as controls. A total of 125 ceramic specimens (n=25) were fabricated to a final specimen dimension of 12×12 mm and in thicknesses of 1.0, 1.25, 1.5, 1.75, and 2.0 mm according to the manufacturers’ recommendations. The CIELab color space for all specimens placed against a white and black ground was measured with a spectrophotometer (CM-2600D), and the translucency parameters were calculated for the materials at various thicknesses. A light-polymerizing unit (DEMI LED) was used to polymerize the resin cement (Variolink II) placed beneath the ceramic specimens. Transmitted light intensity from the polymerization unit beneath the ceramic specimens was measured by using a spectrophotometer (MARC Resin Calibrator), and the transmittance of each specimen was calculated. The coefficient of absorption of each material was calculated from the regression analysis between the natural log of transmittance and specimen thickness. The degree of conversion of resin cement was measured by using a Fourier transformation infrared (FTIR) spectrophotometer. The results were analyzed by using 2-way ANOVA (α=.05). The relationship between the transmittance and the translucency parameter was evaluated by plotting the transmittance against the translucency parameter value of each specimen. Results The translucency parameter decreased with increasing thickness in all 5 material groups. All anatomic-contour zirconia had lower translucency parameters than e-max CAD (P<.001). The same results were found for the intensity of the transmitted light (P<.001). Both A2 shade anatomic-contour zirconia (Zirlux and Luxisse) showed significantly lower light transmittance than a generic shade anatomic-contour zirconia (CAP FZ) (P<.001). The coefficients of absorption were found to range from 0.63 to 1.72 mm-1, and reflectance from 0.10 to 0.25. The results from the degree of conversion of resin cement after polymerization through 1 to 2 mm of specimens showed a significantly higher degree of conversion in the e.max group than in all other groups (P<.001). The correlation between translucency parameter and the intensity of the transmitted light suggested that the relationship was shade dependent. Conclusions The translucency parameter and the transmitted light intensity of ceramic material were influenced by the type of ceramic and the shade and thickness of the ceramic. The combined effects of layer thickness and the intensity of the transmitted light in the A2 shade anatomic-contour zirconia (Zirlux and Luxisse) resulted in a lower degree of conversion in resin cement than in a generic shade anatomic-contour zirconia (CAP FZ) at layer thicknesses of 1.75 and 2 mm.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Supornpun, N., Oster, M., Phasuk, K., & Chu, T.-M. G. (2023). Effects of shade and thickness on the translucency parameter of anatomic-contour zirconia, transmitted light intensity, and degree of conversion of the resin cement. The Journal of Prosthetic Dentistry, 129(1), 213–219. https://doi.org/10.1016/j.prosdent.2021.04.019
ISSN
0022-3913
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
The Journal of Prosthetic Dentistry
Rights
Publisher Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}