Contrast Leakage Patterns from Dynamic Susceptibility Contrast Perfusion MRI in the Grading of Primary Pediatric Brain Tumors

dc.contributor.authorHo, Chang Y.
dc.contributor.authorCardinal, Jeremy S.
dc.contributor.authorKamer, Aaron P.
dc.contributor.authorLin, Chen
dc.contributor.authorKralik, Stephen F.
dc.contributor.departmentDepartment of Radiology and Imaging Sciences, IU School of Medicineen_US
dc.date.accessioned2016-12-21T20:49:47Z
dc.date.available2016-12-21T20:49:47Z
dc.date.issued2016
dc.description.abstractBACKGROUND AND PURPOSE: The pattern of contrast leakage from DSC tissue signal intensity time curves have shown utility in distinguishing adult brain neoplasms, but has limited description in the literature for pediatric brain tumors. The purpose of this study is to evaluate the utility of grading pediatric brain tumors with this technique. MATERIALS AND METHODS: A retrospective review of tissue signal-intensity time curves from 63 pediatric brain tumors with preoperative DSC perfusion MR imaging was performed independently by 2 neuroradiologists. Tissue signal-intensity time curves were generated from ROIs placed in the highest perceived tumor relative CBV. The postbolus portion of the curve was independently classified as returning to baseline, continuing above baseline (T1-dominant contrast leakage), or failing to return to baseline (T2*-dominant contrast leakage). Interobserver agreement of curve classification was evaluated by using the Cohen κ. A consensus classification of curve type was obtained in discrepant cases, and the consensus classification was compared with tumor histology and World Health Organization grade. RESULTS: Tissue signal-intensity time curve classification concordance was 0.69 (95% CI, 0.54–0.84) overall and 0.79 (95% CI, 0.59–0.91) for a T1-dominant contrast leakage pattern. Twenty-five of 25 tumors with consensus T1-dominant contrast leakage were low-grade (positive predictive value, 1.0; 95% CI, 0.83–1.00). By comparison, tumors with consensus T2*-dominant contrast leakage or return to baseline were predominantly high-grade (10/15 and 15/23, respectively) with a high negative predictive value (1.0; 95% CI, 0.83–1.0). For pilomyxoid or pilocytic astrocytomas, a T1-dominant leak demonstrated high sensitivity (0.91; 95% CI, 0.70–0.98) and specificity (0.90, 95% CI, 0.75–0.97). CONCLUSIONS: There was good interobserver agreement in the classification of DSC perfusion tissue signal-intensity time curves for pediatric brain tumors, particularly for T1-dominant leakage. Among patients with pediatric brain tumors, a T1-dominant leakage pattern is highly specific for a low-grade tumor and demonstrates high sensitivity and specificity for pilocytic or pilomyxoid astrocytomas.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationHo, C. Y., Cardinal, J. S., Kamer, A. P., Lin, C., & Kralik, S. F. (2016). Contrast Leakage Patterns from Dynamic Susceptibility Contrast Perfusion MRI in the Grading of Primary Pediatric Brain Tumors. American Journal of Neuroradiology, 37(3), 544–551. https://doi.org/10.3174/ajnr.A4559en_US
dc.identifier.urihttps://hdl.handle.net/1805/11708
dc.language.isoenen_US
dc.relation.isversionof10.3174/ajnr.A4559en_US
dc.relation.journalAmerican Journal of Neuroradiologyen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectprimary brain tumorsen_US
dc.subjectchildhood cancersen_US
dc.subjectdynamic susceptibility contrasten_US
dc.titleContrast Leakage Patterns from Dynamic Susceptibility Contrast Perfusion MRI in the Grading of Primary Pediatric Brain Tumorsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ho_2016_contrast.pdf
Size:
550.4 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: