The Fate of Zone 2 Radiolucencies in Contemporary Highly Porous Acetabular Components: Not All Designs Perform Equally

Date
2021-03
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background: The enhanced frictional resistance of modern ultraporous acetabular components can impede complete seating; however, surgeons expect the enhanced ingrowth surface to resolve polar (zone 2) gaps over time via osseointegration. This study characterized zone 2 radiographic osseointegration in 3 acetabular component designs: 2 highly porous ingrowth and one traditional ongrowth.

Methods: A consecutive cohort of primary total hip arthroplasties was reviewed which utilized 3 different acetabular cup designs: ongrowth titanium with hydroxyapatite (HA), highly porous titanium with machined radial grooves (MRG), and dual-porous titanium substrate with micropore (MP). Radiographic analysis was performed using accepted measurement criteria with particular attention to radiolucent lines.

Results: Seven hundred ninety cases were available for analysis. Initial 1-month radiographs revealed 43.2% of HA, 78.2% of MRG, and 81.0% of MP cups exhibited zone 2 radiolucencies, consistent with incomplete seating. At 1 year, all HA radiolucencies resolved, whereas 46.2% and 34.7% of radiolucencies remained in MRG and MP cups, respectively (P ≤ .005). At minimum 2 years, a significant proportion of zone 2 radiolucencies remained in 46.0% of MRG compared with 23.9% of MP cups and 3.0% of HA cups (P ≤ .007).

Conclusion: The resolution of zone 2 radiolucencies at 1-year and minimum 2-year follow-up signified osseointegration for nearly all HA and most MP cups. Highly porous titanium cups with machined radial grooves demonstrated persistent zone 2 radiolucencies at 1 year and beyond. Given reports of early loosening with this particular acetabular implant, further follow-up is warranted as this study highlights that not all contemporary highly porous metal acetabular components perform equally.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Zielinski MR, Deckard ER, Meneghini RM. The Fate of Zone 2 Radiolucencies in Contemporary Highly Porous Acetabular Components: Not All Designs Perform Equally. Arthroplast Today. 2021;8:96-102. Published 2021 Mar 7. doi:10.1016/j.artd.2021.01.018
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Arthroplasty Today
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}