Aerosol and droplet generation from mandible and midface fixation: Surgical risk in the pandemic era

Abstract

Purpose The COVID-19 pandemic has led to concerns over transmission risk from healthcare procedures, especially when operating in the head and neck such as during surgical repair of facial fractures. This study aims to quantify aerosol and droplet generation from mandibular and midface open fixation and measure mitigation of airborne particles by a smoke evacuating electrocautery hand piece.

Materials and methods The soft tissue of the bilateral mandible and midface of two fresh frozen cadaveric specimens was infiltrated using a 0.1% fluorescein solution. Surgical fixation via oral vestibular approach was performed on each of these sites. Droplet splatter on the surgeon's chest, facemask, and up to 198.12 cm (6.5 ft) away from each surgical site was measured against a blue background under ultraviolet-A (UV-A) light. Aerosol generation was measured using an optical particle sizer.

Results No visible droplet contamination was observed for any trials of mandible or midface fixation. Total aerosolized particle counts from 0.300–10.000 μm were increased compared to baseline following each use of standard electrocautery (n = 4, p < 0.001) but not with use of a suction evacuating electrocautery hand piece (n = 4, p = 0.103). Total particle counts were also increased during use of the powered drill (n = 8, p < 0.001).

Conclusions Risk from visible droplets during mandible and midface fixation is low. However, significant increases in aerosolized particles were measured after electrocautery use and during powered drilling. Aerosol dispersion is significantly decreased with the use of a smoke evacuating electrocautery hand piece.

Description
This article is made available for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Ye, M. J., Sharma, D., Campiti, V. J., Rubel, K. E., Burgin, S. J., Illing, E. A., ... & Shipchandler, T. Z. (2021). Aerosol and droplet generation from mandible and midface fixation: surgical risk in the pandemic era. American Journal of Otolaryngology, 42(1), 102829. https://doi.org/10.1016/j.amjoto.2020.102829
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
American Journal of Otolaryngology
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}