The Dosimetric Outcome of a Rotational Planning Target Volume in Patients With Oropharyngeal Cancers
Date
Language
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
An isotropic expanded Planning Target Volume (PTV) neglects patient's off-axis rotation. This study designs a rotational PTV that is used instead of the standard 3-mm Clinical Target Volume (CTV) expanded PTV in oropharyngeal cancers with the goal to reduce pharyngeal constrictor muscle (PCM) mean dose. 10 patients were retrospectively evaluated. For off-axis rotation, the image was rotated around the longitudinal axis (cervical spinal canal) ± 5 degrees. These new CTVs were combined to form the rotational PTV. The standard and rotational treatment plans were designed with the goal to keep the superior and middle PCM-CTV70 mean dose to less than 50 Gy. There were a 355 cGy reduction in the superior PCM mean dose (form 5332 to 4977 cGy) and a 506 cGy reduction in middle PCM mean dose (from 4185 to 3679 cGy). 60% of patients may have at least a 20% reduction in dysphagia probability based on a Normal Tissue Complication Probability (NTCP) formula. The superior and middle PCM mean dose were reduced to less than 50 Gy in 40 and 20% of cases. There was an association between superior PCM mean dose and overlap volume of PTV70 and superior PCM in both standard (r = 0.92, p = 0.001) and rotational (r = 0.84, p = 0.002) plans. This association was present for middle PCM and PTV70 (r = 0.52, p = 0.02 and r = 0.62, p = 0.006). Rotational PTV can lower the mean dose to superior and middle PCMs, ultimately leading to lower dysphagia rates.