The effects of spherical aberration on multiphoton fluorescence excitation microscopy

dc.contributor.authorYoung, P. A.
dc.contributor.authorClendenon, S. G.
dc.contributor.authorByars, J. M.
dc.contributor.authorDecca, R. S.
dc.contributor.authorDunn, K. W.
dc.contributor.departmentDepartment of Medicine, IU School of Medicineen_US
dc.date.accessioned2016-04-15T15:56:49Z
dc.date.available2016-04-15T15:56:49Z
dc.date.issued2011-05
dc.description.abstractMultiphoton fluorescence excitation microscopy is almost invariably conducted with samples whose refractive index differ from that of the objective immersion medium, conditions that cause spherical aberration. Due to the quadratic nature of multiphoton fluorescence excitation, spherical aberration is expected to profoundly affect the depth dependence of fluorescence excitation. In order to determine the effect of refractive index mismatch in multiphoton fluorescence excitation microscopy, we measured signal attenuation, photobleaching rates and resolution degradation with depth in homogeneous samples with minimal light scattering and absorption over a range of refractive indices. These studies demonstrate that signal levels and resolution both rapidly decline with depth into refractive index mismatched samples. Analyses of photobleaching rates indicate that the preponderance of signal attenuation with depth results from decreased rates of fluorescence excitation, even in a system with a descanned emission collection pathway. Similar results were obtained in analyses of fluorescence microspheres embedded in rat kidney tissue, demonstrating that spherical aberration is an important limiting factor in multiphoton fluorescence excitation microscopy of biological samples.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationYoung, P. A., Clendenon, S. G., Byars, J. M., Decca, R. S., & Dunn, K. W. (2011). The effects of spherical aberration on multiphoton fluorescence excitation microscopy. Journal of Microscopy, 242(2), 157–165. http://doi.org/10.1111/j.1365-2818.2010.03449.xen_US
dc.identifier.issn1365-2818en_US
dc.identifier.urihttps://hdl.handle.net/1805/9315
dc.language.isoen_USen_US
dc.publisherWiley Blackwell (Blackwell Publishing)en_US
dc.relation.isversionof10.1111/j.1365-2818.2010.03449.xen_US
dc.relation.journalJournal of Microscopyen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectMicroscopy, Fluorescence, Multiphotonen_US
dc.subjectmethodsen_US
dc.titleThe effects of spherical aberration on multiphoton fluorescence excitation microscopyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms693485.pdf
Size:
1.09 MB
Format:
Adobe Portable Document Format
Description:
Author's manuscript
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: