Resonant Acoustic Rheometry to Measure Coagulation Kinetics in Hemophilia A and Healthy Plasma: A Novel Viscoelastic Method

dc.contributor.authorLi, Weiping
dc.contributor.authorHobson, Eric C.
dc.contributor.authorBunch, Connor M.
dc.contributor.authorMiller, Joseph B.
dc.contributor.authorNehme, Jimmy
dc.contributor.authorKwaan, Hau C.
dc.contributor.authorWalsh, Mark M.
dc.contributor.authorMcCurdy, Michael T.
dc.contributor.authorAversa, John G.
dc.contributor.authorThomas, Anthony V.
dc.contributor.authorZackariya, Nuha
dc.contributor.authorThomas, Samuel J.
dc.contributor.authorSmith, Stephanie A.
dc.contributor.authorCook, Bernard C.
dc.contributor.authorBoyd, Bryan
dc.contributor.authorStegemann, Jan P.
dc.contributor.authorDeng, Cheri X.
dc.contributor.departmentSurgery, School of Medicine
dc.date.accessioned2024-06-26T16:26:28Z
dc.date.available2024-06-26T16:26:28Z
dc.date.issued2023
dc.description.abstractCompared with conventional coagulation tests and factor-specific assays, viscoelastic hemostatic assays (VHAs) can provide a more thorough evaluation of clot formation and lysis but have several limitations including clot deformation. In this proof-of-concept study, we test a noncontact technique, termed resonant acoustic rheometry (RAR), for measuring the kinetics of human plasma coagulation. Specifically, RAR utilizes a dual-mode ultrasound technique to induce and detect surface oscillation of blood samples without direct physical contact and measures the resonant frequency of the surface oscillation over time, which is reflective of the viscoelasticity of the sample. Analysis of RAR results of normal plasma allowed defining a set of parameters for quantifying coagulation. RAR detected a flat-line tracing of resonant frequency in hemophilia A plasma that was corrected with the addition of tissue factor. Our RAR results captured the kinetics of plasma coagulation and the newly defined RAR parameters correlated with increasing tissue factor concentration in both healthy and hemophilia A plasma. These findings demonstrate the feasibility of RAR as a novel approach for VHA, providing the foundation for future studies to compare RAR parameters to conventional coagulation tests, factor-specific assays, and VHA parameters.
dc.eprint.versionAuthor's manuscript
dc.identifier.citationLi W, Hobson EC, Bunch CM, et al. Resonant Acoustic Rheometry to Measure Coagulation Kinetics in Hemophilia A and Healthy Plasma: A Novel Viscoelastic Method. Semin Thromb Hemost. 2023;49(2):201-208. doi:10.1055/s-0042-1757896
dc.identifier.urihttps://hdl.handle.net/1805/41924
dc.language.isoen_US
dc.publisherThieme
dc.relation.isversionof10.1055/s-0042-1757896
dc.relation.journalSeminars in Thrombosis and Hemostasis
dc.rightsPublisher Policy
dc.sourcePMC
dc.subjectHemophilia A
dc.subjectHemostatic
dc.subjectPoint of care
dc.subjectThromboelastography
dc.subjectUltrasonic
dc.titleResonant Acoustic Rheometry to Measure Coagulation Kinetics in Hemophilia A and Healthy Plasma: A Novel Viscoelastic Method
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Li2023Resonant-AAM.pdf
Size:
1.03 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.04 KB
Format:
Item-specific license agreed upon to submission
Description: