Primary Evaluation of Shape Recovery of Orthodontic Aligners Fabricated from Shape Memory Polymer (A Typodont Study)

dc.contributor.authorElshazly, Tarek M.
dc.contributor.authorKeilig, Ludger
dc.contributor.authorAlkabani, Yasmine
dc.contributor.authorGhoneima, Ahmed
dc.contributor.authorAbuzayda, Moosa
dc.contributor.authorTalaat, Sameh
dc.contributor.authorBourauel, Christoph P.
dc.contributor.departmentOrthodontics and Oral Facial Genetics, School of Dentistry
dc.date.accessioned2024-10-22T09:53:25Z
dc.date.available2024-10-22T09:53:25Z
dc.date.issued2021-03-10
dc.description.abstractAs an innovative approach to overcome the rate-limiting staging of conventional aligners, using shape memory polymers (SMPs) as aligners’ materials was investigated in this in vitro study. The ability of SMPs to shape recover and consequently move tooth, upon appropriate stimuli, was evaluated on a typodont model before clinical application. The study design was to achieve 1.9 mm correction movement of an upper central incisor by one aligner after multiple steps/activation. A custom-made aligned typodont model with a movable upper central incisor was scanned. Using an orthodontic software and a 3D printer, resin-models were generated. Seven aligners of ClearX sheets (SMPs) were fabricated by thermoforming on the resin aligned model. Each aligner was tested for repositioning of the central incisor in the typodont model. The model was scanned after each step and the corrective movement was measured through the superimposition of scans. Results showed that the total correction efficiency of the SMPs’ aligner was ≈93% (1.76 mm). The corrective movement was 0.94 ± 0.04 mm after the reforming step, 0.66 ± 0.07 mm after the first activation step, and 0.15 ± 0.10 mm after the second activation step. It was concluded that aligners made of SMPs could have a promising future-use in orthodontic aesthetic treatment.
dc.eprint.versionFinal published version
dc.identifier.citationElshazly TM, Keilig L, Alkabani Y, et al. Primary Evaluation of Shape Recovery of Orthodontic Aligners Fabricated from Shape Memory Polymer (A Typodont Study). Dent J (Basel). 2021;9(3):31. Published 2021 Mar 10. doi:10.3390/dj9030031
dc.identifier.urihttps://hdl.handle.net/1805/44124
dc.language.isoen_US
dc.publisherMDPI
dc.relation.isversionof10.3390/dj9030031
dc.relation.journalDentistry Journal
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.sourcePMC
dc.subjectOrthodontics
dc.subjectSmart polymers
dc.subjectClear aligners
dc.subjectOrthodontic appliance
dc.subjectTypodont
dc.subject3D printers
dc.subjectDentistry
dc.subjectDigital workflow
dc.titlePrimary Evaluation of Shape Recovery of Orthodontic Aligners Fabricated from Shape Memory Polymer (A Typodont Study)
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Elshazly2021Primary-CCBY.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.04 KB
Format:
Item-specific license agreed upon to submission
Description: