Electronic Heart (ECG) Monitoring at Birth and Newborn Resuscitation
Date
Language
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
Background: Approximately 10% of newborns require assistance at delivery, and heart rate (HR) is the primary vital sign providers use to guide resuscitation methods. In 2016, the American Heart Association (AHA) suggested electrocardiogram in the delivery room (DR-ECG) to measure heart rate during resuscitation. This study aimed to compare the frequency of resuscitation methods used before and after implementation of the AHA recommendations. Methods: This longitudinal retrospective cohort study compared a pre-implementation (2015) cohort with two post-implementation cohorts (2017, 2021) at our Level IV neonatal intensive care unit. Results: An initial increase in chest compressions at birth associated with the introduction of DR-ECG monitoring was mitigated by focused educational interventions on effective ventilation. Implementation was accompanied by no changes in neonatal mortality. Conclusions: Investigation of neonatal outcomes during the ongoing incorporation of DR-ECG may help our understanding of human and system factors, identify ways to optimize resuscitation team performance, and assess the impact of targeted training initiatives on clinical outcomes.