Does the presence of an occlusal indicator product affect the contact forces between full dentitions?

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2017
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wiley
Abstract

Studies have explored occlusal marking interpretation, repeatability and accuracy. But, when an occlusion detection product is interposed between teeth, direct tooth–tooth occlusal contact relationships are replaced by tooth-material-tooth structures. Thus, the marks cannot reflect the original contacts. This has been shown for single tooth pair contacts. The purpose of this laboratory study was to similarly examine full dentitions. A dentiform was set into Class I centric occlusion with the mandible supported by a load cell. The maxillary arch was guided by precision slides. As the weighted (~52 N) upper assembly was lowered onto and raised off the mandibular arch, the loads on the mandible were measured. With and without (control) occlusal marking material, the steps were as follows: (cleaning – control 1 – material 1) … (cleaning – control 6 – material 6). The six materials were as follows: Accufilm I and II, Rudischhauser Thick and Thin, Hanel Articulating Silk and T-Scan. Then, the six sets of (cleaning – control – material) measurements were repeated with the mandibular assembly shifted, in turn, by 0·1 mm in the Anterior, Posterior, Right and Left directions. The five (Centric and four 0·1 mm shifted) occlusal relationships produced grossly different tooth–tooth (control) load profiles. And, in general, these controls were affected, in different ways, by the marking products. Among the five conventional products, the Rudischhausers fared the worst and the electronic T-Scan was an extreme outlier. Thus, in general, popular occlusal detection products alter the occlusal contact forces, and therefore, their markings cannot characterise the actual occlusion.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Mitchem, J. A., Katona, T. R. and Moser, E. A. S. (2017), Does the presence of an occlusal indicator product affect the contact forces between full dentitions?. J Oral Rehabil. Accepted Author Manuscript. doi:10.1111/joor.12543
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Oral Rehabilitation
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}