Second-generation distal attachment cuff improves adenoma detection rate: meta-analysis of randomized controlled trials

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2021-03
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background and Aims Multiple randomized controlled trials (RCTs) using the second-generation distal attachment cuff device (Endocuff Vision; Olympus America, Center Valley, Pa, USA) have reported conflicting results in improving adenoma detection rate (ADR) compared with standard high-definition colonoscopy without the distal attachment. We conducted a systematic review and meta-analysis of RCTs to compare outcomes between second-generation cuff colonoscopy (CC) versus colonoscopy without the distal attachment (standard colonoscopy [SC]). Methods An electronic literature search was performed using PubMed, Google Scholar, Embase, and Cochrane Library through May 2020. The primary outcome was reporting of ADR, and secondary outcomes were polyp detection rate (PDR), mean withdrawal time, mean adenomas per colonoscopy (APC), sessile serrated lesion detection rate, and adverse events. Pooled rates and risk ratios (RRs) with 95% confidence intervals were reported. Results Eight RCTs with 5695 patients were included in the final analysis, with 2862 patients (mean age, 62.8 years; 52.9% men) in the CC group and 2833 patients (mean age, 62.6 years; 54.2% men) in the SC group. Compared with SC, use of CC was associated with a significant improvement in ADR (49.8% vs 45.6%, respectively; RR, 1.12; P = .02), PDR (58.1% vs 53%, respectively; RR, 1.12; P = .009), and APC ( P < .01). Furthermore, use of CC had a .93-minute lower mean withdrawal time ( P < .01) when compared with SC. The difference in ADR was larger in the screening/surveillance population (6.5%, P = .02) and when used by endoscopists with ADRs <30% (9.4%, P = .03). Conclusions The results of this meta-analysis of randomized trials show a significant improvement in ADR and APC with shorter withdrawal times using the second-generation cuff device compared with SC.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Patel, H. K., Chandrasekar, V. T., Srinivasan, S., Patel, S. K., Dasari, C. S., Singh, M., Cam, E. L., Spadaccini, M., Rex, D., & Sharma, P. (2021). Second-generation distal attachment cuff improves adenoma detection rate: Meta-analysis of randomized controlled trials. Gastrointestinal Endoscopy, 93(3), P544-553.E7. https://doi.org/10.1016/j.gie.2020.09.045
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Gastrointestinal Endoscopy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}