An analysis of hearing aid fittings in adults using cochlear implants and contralateral hearing aids

dc.contributor.authorHarris, Michael S.
dc.contributor.authorHay-McCutcheon, Marcia
dc.contributor.departmentOtolaryngology -- Head and Neck Surgery, School of Medicineen_US
dc.date.accessioned2018-03-26T13:22:23Z
dc.date.available2018-03-26T13:22:23Z
dc.date.issued2010-12
dc.description.abstractOBJECTIVES/HYPOTHESIS: The objective of this study was to assess the appropriateness of hearing aid fittings within a sample of adult cochlear implant recipients who use a hearing aid in the contralateral ear (i.e., bimodal stimulation). METHODS: The hearing aid gain was measured using real ear testing for 14 postlingually deaf English-speaking adults who use a cochlear implant in the contralateral ear. Unaided and aided audiometric testing assessed the degree of functional gain derived from hearing aid use. RESULTS: On average, the target to actual output level difference was within 10 dB only at frequencies of 750 Hz and 1,000 Hz. Only 1 of the 14 study participants had a hearing aid for which the majority of the tested frequencies were within 10 dB of the target gain. In addition, a greater amount of functional gain (i.e., the increase in unaided behavioral thresholds after amplification) was provided for lower frequencies than higher frequencies. CONCLUSIONS: Hearing aid settings in our sample were suboptimal and may be regarded as a contributing factor to the variability in bimodal benefit. Refining hearing aid fitting strategies tailored to the needs of the concurrent cochlear implant and hearing aid user is recommended.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationHarris, M. S., & Hay-McCutcheon, M. (2010). An analysis of hearing aid fittings in adults using cochlear implants and contralateral hearing aids. The Laryngoscope, 120(12), 2484–2488. http://doi.org/10.1002/lary.21148en_US
dc.identifier.urihttps://hdl.handle.net/1805/15702
dc.language.isoen_USen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1002/lary.21148en_US
dc.relation.journalThe Laryngoscopeen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectAdulten_US
dc.subjectBimodal stimulationen_US
dc.subjectCochlear implantsen_US
dc.subjectDeafnessen_US
dc.subjectHearing aidsen_US
dc.titleAn analysis of hearing aid fittings in adults using cochlear implants and contralateral hearing aidsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms874798.pdf
Size:
237.81 KB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: