Effects of Angular Resolution and b Value on Diffusion Tensor Imaging in Knee Joint

dc.contributor.authorZhao, Qi
dc.contributor.authorRidout, Rees P.
dc.contributor.authorShen, Jikai
dc.contributor.authorWang, Nian
dc.contributor.departmentRadiology and Imaging Sciences, School of Medicineen_US
dc.date.accessioned2023-07-07T12:34:23Z
dc.date.available2023-07-07T12:34:23Z
dc.date.issued2021
dc.description.abstractObjective: To investigate the influences of the diffusion gradient directions (angular resolution) and the strength of the diffusion gradient (b value) on diffusion tensor imaging (DTI) metrics and tractography of various connective tissues in knee joint. Design: Two rat knee joints were scanned on a preclinical 9.4-T system using a 3-dimensional diffusion-weighted spin echo pulse sequence. One protocol with b value of 500, 1500, and 2500 s/mm2 were acquired separately using 43 diffusion gradient directions. The other protocol with b value of 1000 s/mm2 was performed using 147 diffusion gradient directions. The in-plane resolution was 45 µm isotropic. Fractional anisotropy (FA) and mean diffusivity (MD) were compared at different angular resolution. Tractography was quantitatively evaluated at different b values and angular resolutions in cartilage, ligament, meniscus, and growth plate. Results: The ligament showed higher FA value compared with growth plate and cartilage. The FA values were largely overestimated at the angular resolution of 6. Compared with FA, MD showed less sensitivity to the angular resolution. The fiber tracking was failed at low angular resolution (6 diffusion gradient directions) or high b value (2500 s/mm2). The quantitative measurements of tract length and track volume were strongly dependent on angular resolution and b value. Conclusions: To obtain consistent DTI outputs and tractography in knee joint, the scan may require a proper b value (ranging from 500 to 1500 s/mm2) and sufficient angular resolution (>14) with signal-to-noise ratio >10.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationZhao Q, Ridout RP, Shen J, Wang N. Effects of Angular Resolution and b Value on Diffusion Tensor Imaging in Knee Joint. Cartilage. 2021;13(2_suppl):295S-303S. doi:10.1177/19476035211007909en_US
dc.identifier.urihttps://hdl.handle.net/1805/34201
dc.language.isoen_USen_US
dc.publisherSageen_US
dc.relation.isversionof10.1177/19476035211007909en_US
dc.relation.journalCartilageen_US
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.sourcePMCen_US
dc.subjectCartilageen_US
dc.subjectDiffusion tensor imaging (DTI)en_US
dc.subjectKneeen_US
dc.subjectTractographyen_US
dc.titleEffects of Angular Resolution and b Value on Diffusion Tensor Imaging in Knee Jointen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10.1177_19476035211007909.pdf
Size:
2.01 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: