Combination of Mucosa-Exposure Device and Computer-Aided Detection for Adenoma Detection During Colonoscopy: A Randomized Trial

Abstract

Background & Aims Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. Methods Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. Results From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00–1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04–1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69–1.14; P = .38). Conclusions The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Spadaccini, M., Hassan, C., Rondonotti, E., Antonelli, G., Andrisani, G., Lollo, G., Auriemma, F., Iacopini, F., Facciorusso, A., Maselli, R., Fugazza, A., Bambina Bergna, I. M., Cereatti, F., Mangiavillano, B., Radaelli, F., Di Matteo, F., Gross, S. A., Sharma, P., Mori, Y., … Schilirò, A. (2023). Combination of mucosa-exposure device and computer-aided detection for Adenoma Detection during Colonoscopy: A randomized trial. Gastroenterology, 165(1), P244-251.E3. https://doi.org/10.1053/j.gastro.2023.03.237
ISSN
Publisher
37061169
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Gastroenterology
Rights
Publisher Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}