dc.description.abstractStudy objectives: Polysomnography (PSG) is increasingly used in the assessment of infants. Newborn PSG reference values based on recent standardization are not available. This study provides reference values for PSG variables in healthy newborn infants. Methods: Cross-sectional study of normal term newborn infants using standardized PSG collection and American Academy of Sleep Medicine interpretation criteria. Results: Thirty infants born between 37 and 42 weeks gestation underwent PSG testing before 30 days of age (mean 19.6 days). The infants had a mean sleep efficiency of 71% with average proportions of transitional, NREM and REM sleep estimated at 16.1%, 43.3% and 40.6% respectively. Mean arousal index was 14.7 events/h with respiratory arousal index of 1.2 events/h. Mean apnea-hypopnea index (AHI) was 14.9 events/h. Central, obstructive, and mixed apnea indices were 5.4, 2.3, and 1.2 events/h respectively. Mean oxygen saturation in sleep was 97.9% with a nadir of 84.4%. Mean end tidal CO2 was 35.4 mmHg with an average of 6.2% of sleep time spent above end-tidal CO2 45 mmHg and 0.6% above 50 mmHg. Conclusions: The sleep efficiency was significantly lower and the AHI was significantly higher compared to healthy children older than 1 year. The AHI was also higher than reported in healthy infants older than 1 month. These findings suggest current severity classifications of sleep apnea may not apply to newborn infants.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationDaftary AS, Jalou HE, Shively L, Slaven JE, Davis SD. Polysomnography Reference Values in Healthy Newborns. J Clin Sleep Med. 2019 Mar 15;15(3):437-443. doi: 10.5664/jcsm.7670. PMID: 30853051; PMCID: PMC6411184.en_US
dc.identifier.urihttps://hdl.handle.net/1805/28587
dc.language.isoen_USen_US
dc.publisherAmerican Academy of Sleep Medicineen_US
dc.relation.isversionof10.5664/jcsm.7670en_US
dc.relation.journalJournal of Clinical Sleep Medicineen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectApneaen_US
dc.subjectInfanten_US
dc.subjectPolysomnographyen_US
dc.subjectSleep studyen_US
dc.titlePolysomnography Reference Values in Healthy Newbornsen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jcsm.15.3437.pdf
Size:
988.12 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: