Dosimetric Comparison of Treatment Techniques: Brachytherapy, Intensity- Modulated Radiation Therapy, and Proton Beam in Partial Breast Irradiation

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2015
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract

Purpose: To perform a dosimetric comparison of 3 accelerated partial breast irradiation techniques: catheter-based brachytherapy (BT), intensity-modulated radiation therapy (IMRT), and proton beam therapy (PBT).

Patients and Methods: Twelve patients with left-sided breast cancer treated with SAVI (Strut-Adjusted Volume Implant) were selected in this study. The original BT plans were compared with optimum plans using IMRT and PBT for 34 Gy (RBE) with 1.1 RBE in 10 fractions using identical parameters for target and organs at risk.

Results: Significant reduction in maximum dose to the ipsilateral breast was observed with PBT and IMRT (mean 108.58% [PBT] versus 107.78% [IMRT] versus 2194.43% [BT], P = .001 for both PBT and IMRT compared to BT). The mean dose to the heart was 0%, 1.38%, and 3.85%, for PBT, IMRT, and BT, respectively (P < .001 and P = .026). The chest wall mean dose was 10.07%, 14.65%, and 29.44% for PBT, IMRT, and BT, respectively (P = .001 and .013 compared to BT). The PBT was superior in reducing the mean ipsilateral lung dose (mean 0.04% versus 2.13% versus 5.4%, P = .025 and P < .001). There was no statistically significant difference in the maximum dose to the ipsilateral lung, chest wall, 3-mm skin rind or in the mean ipsilateral breast V50% among the 3 techniques (P = .168, .405, .067, and .780, respectively). PBT exhibited the greatest mean dose homogeneity index of 4.75 compared to 7.18 for IMRT (P = .001) and 195.82 for BT (P < .001). All techniques resulted in similar dose conformality (P = .143).

Conclusion: This study confirms the dosimetric feasibility of PBT and IMRT to lower dose to organs at risk while still maintaining high target dose conformality. Though the results of this comparison are promising, continued clinical research is needed to better define the role of PBT and IMRT in the accelerated partial breast irradiation treatment of early-stage breast cancer.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Hansen, T. M., Bartlett, G. K., Mannina Jr, E. M., Srivastava, S. P., Cox, J. A., & Das, I. J. (2015). Dosimetric Comparison of Treatment Techniques: Brachytherapy, Intensity-Modulated Radiation Therapy, and Proton Beam in Partial Breast Irradiation. International Journal of Particle Therapy.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
International Journal of Particle Therapy
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}