Mechanical circulatory support--either ventricular assist device (VAD, left-sided systemic support) or cavopulmonary assist device (CPAD, right-sided support)--has been suggested as treatment for Fontan failure. The selection of left- versus right-sided support for failing Fontan has not been previously defined. Computer simulation and mock circulation models of pediatric Fontan patients (15-25 kg) with diastolic, systolic, and combined systolic and diastolic dysfunction were developed. The global circulatory response to assisted Fontan flow using VAD (HeartWare HVAD, Miami Lakes, FL) support, CPAD (Viscous Impeller Pump, Indianapolis, IN) support, and combined VAD and CPAD support was evaluated. Cavopulmonary assist improves failing Fontan circulation during diastolic dysfunction but preserved systolic function. In the presence of systolic dysfunction and elevated ventricular end-diastolic pressure (VEDP), VAD support augments cardiac output and diminishes VEDP, while increased preload with cavopulmonary assist may worsen circulatory status. Fontan circulation can be stabilized to biventricular values with modest cavopulmonary assist during diastolic dysfunction. Systemic VAD support may be preferable to maintain systemic output during systolic dysfunction. Both systemic and cavopulmonary support may provide best outcome during combined systolic and diastolic dysfunction. These findings may be useful to guide clinical cavopulmonary assist strategies in failing Fontan circulations.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Giridharan, G. A., Ising, M., Sobieski, M. A., Koenig, S. C., Chen, J., Frankel, S., & Rodefeld, M. D. (2014). Cavopulmonary assist for the failing Fontan circulation: Impact of ventricular function on mechanical support strategy. ASAIO Journal (American Society for Artificial Internal Organs : 1992), 60(6), 707–715. http://doi.org/10.1097/MAT.0000000000000135
ISSN
1538-943X
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
ASAIO journal (American Society for Artificial Internal Organs: 1992)
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}